speed control and test function

- Cr

eo | 

speed contr

ol and test function

The  REMOTE  LED  indicator  displays  the  current 
status as:

•   

OFF - the IR receiver is ‘off’ and remote control is 

      not possible.

•   

FLASHING - the current IR channel setting is 

      displayed on channel B’s LED display and can be 
      altered using either channel A or B +/- power 
      adjust buttons.

•   

ON - the IR receiver is ‘on’ and the Creo can be 

      controlled using one of Bowens IR remote 
      controls.

Depending on the set IR channel on the Creo and 
the  IR  channel  set  on  one  of  Bowens  IR  remote 
controls, the Creo will accept IR signals as follows:

•   

CHANNEL    0 - ANY incoming channel from 

      0 (ALL) - 8.
•   

CHANNEL    1-8 - only a matching IR channel 

      from 1-8 or 0 (ALL).

NB.  If  the  Creo  trigger  option  is  set  to  CELL 
then  using  an  IR  remote  control  too  close  to  the 
generator  (<1m)  it  may  cause  the  generator  to  be 
triggered.

speed

 

control

The 

SPEED button on the Creo control panel makes 

it  possible  to  utilise  the  available  mains  power 
supply  by  adjusting  and  optimising  the  maximum 
possible speed and load without blowing fuses or 
trip switches. The Creo’s amperage load from the 
mains power supply corresponds proportionally to 
the speed setting.

The SPEED control button is used to select one of 
four recycling speed settings. The appropriate LED 
indicator will highlight the chosen setting:

•   

25%  -  the  slowest  recycling  speed  (25%)  is 

approximately  four  times  as  long  as  the  fastest 
(100%)  recycling  speed.  This  option  should  be 
selected  when  the  Creo  is  connected  to  a  mains 
power supply with weak fuses or inadequate sized 
wiring,  or  if  you  are  uncertain  as  to  how  well  the 
mains power supply is fused. It may also allow three 
or four generators to be connected to the same wall 
outlet or fuse group provided it is adequately fused.

•   

50% - this option is twice as long as the fastest 

      100%) recycling speed. This setting will allow 
      two generators to be attached to the same wall
      outlet / fuse group (provided adequately fused).

•   

75% - this option is only slightly longer than 

      the fastest (100%) recycling speed. It reduces 
      the load by 25% and may prevent sensitive fuses 
      from blowing.

•   

100% - this is the fastest recycling speed. Only 

      one generator should be connected to any one 
      power outlet or fuse group and this should be 
      adequately rated and fused.

DUTY  CYCLE  -  for  the  longest  service  life  it  is 
recommended  that  the  user  always  selects  the 
slowest  SPEED  that  is  consistent  with  the  users 
requirements.  The  Creo  is  designed  to  be  able  to 
flash up to 1000 times at 100% (full power) per hour. 
It is not recommended to run harder than necessary 
due to the effect on the life of the flash tube(s).

test

 

function

The Flash/Open Test Button is used to test all light 
settings  are  correct  and  that  the  functionality  is 
as expected. When the Flash/Open Test Button is 
pressed,  any  connected  heads  will  flash  and  the 
‘green  ready  indicator  ring’  will  rotate  to  indicate 
charging.

Summary of Contents for CREO 1200

Page 1: ...Owner s Handbook...

Page 2: ...judged to have experienced any of the following points failure to follow working instructions correctly accidental or willful damage misuse alteration or repair by a non authorised Bowens service repa...

Page 3: ...ch turn power OFF before before fitting or removing any flash heads Avoid placing cables where they can be tripped over Protect from heavy sharp or hot objects which may cause damage and replace damag...

Page 4: ...ling Mode Button PG 7 I Flash Open Test Button PG 9 J Mains AC Power Connection K Radio Trigger Card Slot PG 7 L Channel B Socket M Channel B LED Display N Power On Off Button O Channel B 1 Stop Power...

Page 5: ...ators 2 Channel A Power Adjust 3 Modelling On Off 4 Ready Indications 5 Channel Select 6 Channel B Power Adjust 7 Modelling Mode 8 Sync Options 9 Flash Open Test A Accessory Release Latch B Flash Tube...

Page 6: ...us beep until the flash power adjust button is released The generator will not alter the actual power level setting until a short period after the user has stopped changing the setting this is to avoi...

Page 7: ...ach channel will be displayed on the appropriate channel LED displays The modelling output setting for each channel can then be adjusted independently by using the STOPS and TENTHS buttons regardless...

Page 8: ...dicate a button press Because of the fast recharging capabilities of the Creo the lamps may appear to not dim with low flash power settings NB The dim ready indication will only be enabled if the mode...

Page 9: ...ycling speed 25 is approximately four times as long as the fastest 100 recycling speed This option should be selected when the Creo is connected to a mains power supply with weak fuses or inadequate s...

Page 10: ...und and removed OVERHEAT if the charge limiter fails to prevent the temperature rising then the recharging will stop completely This will be indicated by OH on both channel LED displays The generator...

Page 11: ...0 4 0 80K Colour Stability Energy Range 10 0 2 0 175K Creo 2400 Rated Energy F10 2400Ws Input Power Supply 100 127V 200 240V 50 60Hz Automatic Multi Voltage Yes use appropriately rated modelling lamp...

Page 12: ...O 2400 BW 9000 CREO FLASH HEAD BW 7760 FLASH TUBE CLEAR BW 3019 MODELLING LAMP 230V 650W BW2503 300W BW2504 MODELLING LAMP 117V 300W BW7515 GLASS DOME UV COATED BW 2981 GLASS DOME CLEAR BW 2982 GLASS...

Reviews: