Bowens CREO 1200 Owner'S Handbook Manual Download Page 7

modelling options and synchronisation

- Cr

eo | 

modelling options and synchr

onisation

modelling

 

mode

 

options

The 

MODEL  button  on  the  Creo  control  panel 

switches  the  modelling  lamp  on  and  off  for  any 
connected  flash  heads.  The  associated  LED 
indicator  will  illuminate  when  turned  ‘on’.  If  the 
modelling  lamps  are  switched  ‘on’  the  user  can 
then  select  a  modelling  mode.  A  single  press  of 
the 

MODE  button  will  scroll  through  the  various 

modelling  mode  options;  the  associated  LED 
indicator will illuminate to highlight which mode is 
selected. When the modelling lamps are switched 
‘off’  the  various  ‘modelling  modes’    cannot  be 
selected  or  changed  and  the  LED  indicators  will 
remain ‘off’. Any previous modelling mode settings 
will  be  remembered  and  reverted  to  when  the 
modelling lamps are switched back ‘on’.

NB. Modelling will only work if the modelling switch 
on the Creo flash head is turned ‘on’.

•  

PROP - automatically adjusts the modelling 

      output proportionally to the flash power setting.

•  

AUTO - automatically sets the modelling lamp 

      on the channel with the highest power setting to 
      max.  When in AUTO mode, the modelling output 
      on the  channel with the lowest flash power 

      setting will be set proportionally to the flash 
      power output on the channel with the highest 
      setting. If both channels are set to the same flash 
      power setting then the modelling output on both 
      channels will be set to max.

•  

MAX - sets the modelling on both channels to 

      max regardless of flash power settings.

•  

FREE - when FREE mode is first selected the 

    LED indicator will flash and the modelling 
      intensity on each channel will be displayed on 
      the appropriate channel LED displays. The 
      modelling output setting for each channel 
      can then be adjusted independently by using 
      the STOPS and TENTHS buttons regardless 
      of the flash power setting. Reducing the intensity 
      below ‘1.0’ will turn the modelling lamp ‘off’ 
      and will be indicated on the appropriate channel 
      LED display by showing ‘- -’. The first press of 
      a ‘+’ STOPS or TENTHS button on the associated 
      channel will turn the lamp on at the lowest power 
      setting. When the modelling output has been 
      selected on each channel press the MODE 
      button and the chosen modelling outputs on the 
      appropriate channels will be set; the LED 
      indicator will then stay lit continuously and the 
      channel LED displays will  revert back to 
      showing the flash power levels.

sync

 

options

The Creo generator can be sync’d with a camera in 
a number of ways. Each press of the 

SYNC button 

will  scroll  through  the  various  available  options 
and the appropriate LED indicator will highlight the 
selected option.

•  

OFF - both LED indicators will be switched ‘off’. 

      In this mode the Creo generator will only trigger 
      from a camera or flash meter connected using a 
      sync cord to either 1/4” jack sync sockets (see 
      pack overview on page 4).

•  

CELL - in this mode the Creo will sync via the 

      ‘Photocell / IR Receiver window’. The Creo will 
      trigger when either an IR signal is received or 
      when the photocell detects a flash from another 
      unit.

•  

RADIO - when this option is first selected the 

      appropriate LED indicator will flash for ten 
      seconds. During this ten second window the 
      Creo enters ‘learn mode’. While in ‘learn mode’ 
      the user can sync a Pulsar transmitter with a 
      Pulsar radio receiver card by pressing the 
      TEST button on the Pulsar transmitter at least 
      five times (or until Creo flashes).

Summary of Contents for CREO 1200

Page 1: ...Owner s Handbook...

Page 2: ...judged to have experienced any of the following points failure to follow working instructions correctly accidental or willful damage misuse alteration or repair by a non authorised Bowens service repa...

Page 3: ...ch turn power OFF before before fitting or removing any flash heads Avoid placing cables where they can be tripped over Protect from heavy sharp or hot objects which may cause damage and replace damag...

Page 4: ...ling Mode Button PG 7 I Flash Open Test Button PG 9 J Mains AC Power Connection K Radio Trigger Card Slot PG 7 L Channel B Socket M Channel B LED Display N Power On Off Button O Channel B 1 Stop Power...

Page 5: ...ators 2 Channel A Power Adjust 3 Modelling On Off 4 Ready Indications 5 Channel Select 6 Channel B Power Adjust 7 Modelling Mode 8 Sync Options 9 Flash Open Test A Accessory Release Latch B Flash Tube...

Page 6: ...us beep until the flash power adjust button is released The generator will not alter the actual power level setting until a short period after the user has stopped changing the setting this is to avoi...

Page 7: ...ach channel will be displayed on the appropriate channel LED displays The modelling output setting for each channel can then be adjusted independently by using the STOPS and TENTHS buttons regardless...

Page 8: ...dicate a button press Because of the fast recharging capabilities of the Creo the lamps may appear to not dim with low flash power settings NB The dim ready indication will only be enabled if the mode...

Page 9: ...ycling speed 25 is approximately four times as long as the fastest 100 recycling speed This option should be selected when the Creo is connected to a mains power supply with weak fuses or inadequate s...

Page 10: ...und and removed OVERHEAT if the charge limiter fails to prevent the temperature rising then the recharging will stop completely This will be indicated by OH on both channel LED displays The generator...

Page 11: ...0 4 0 80K Colour Stability Energy Range 10 0 2 0 175K Creo 2400 Rated Energy F10 2400Ws Input Power Supply 100 127V 200 240V 50 60Hz Automatic Multi Voltage Yes use appropriately rated modelling lamp...

Page 12: ...O 2400 BW 9000 CREO FLASH HEAD BW 7760 FLASH TUBE CLEAR BW 3019 MODELLING LAMP 230V 650W BW2503 300W BW2504 MODELLING LAMP 117V 300W BW7515 GLASS DOME UV COATED BW 2981 GLASS DOME CLEAR BW 2982 GLASS...

Reviews: