All Bowens electrical products are covered by a two 
year  warranty  against  any  faulty  design,  materials 
and workmanship.

If  a  product  does  not  work  on  arrival  or  up  to  a 
maximum  period  of  four  weeks  from  the  date  of 
purchase, it should be returned to the dealer/retail 
outlet from where it was purchased, to exchange (if 
available) the faulty unit for a new one; if the faulty 
unit was part of a kit that was purchased, the dealer/
retailer may choose to simply replace the unit and 
not the entire kit. Alternatively the dealer may offer 
to repair the unit as soon as possible at no charge.

If neither an exchange or repair is possible for the 
faulty unit, then a full refund may be made.

If a warranty fault occurs after the initial four week 
period  (and  within  the  max  two  year  warranty 
period),  then  the  unit  should  be  returned  to  the 
dealer, who will arrange to repair the unit as soon as 
possible, at no charge.

This warranty does not apply to consumable items 
such  as  flash  tubes,  modelling  lamps,  fuses  and 
consumable type batteries.

Should  a  unit  be  returned  at  any  time  within  the 
two year warranty period, and it is judged to have 
experienced  any  of  the  following  points,  failure  to 
follow working instructions correctly, accidental or 
willful damage, misuse, alteration or repair by a non 
authorised  Bowens  service/repair  centre,  then  a 
warranty will be deemed invalid and any repairs that 
may need carrying out will be payable by the owner.

The cost of repairs should be notified to the owner, 
by the dealer, in advance of undertaking any work 
that may be required.

No warranty repairs can be undertaken to any units 
without proof of purchase.

All  warranty  repairs  must  be  conducted  with  the 
dealer from where the product was purchased.

Other  terms  and  conditions  may  be  applicable  in 
specific countries, if stated by the dealer at the time  
of purchase.

    Information

warranty

contents

All Bowens products are certified by 
the  CE  mark.  The  CE  certified  mark 
is  a  declaration  of  conformity  to  the 
required  EMC  directives  2004/108/
EC  ‘Electromagnetic  Compatibility’ 
and  2006/95/EC  ‘Low  Voltage 
Directive’.

    Warranty 

 

              2

    Introduction 

 

              3  

    Safety Notes 

 

              3

    Operation

    Creo Pack Overview 

              4

    Creo Head and Remote Overview         5

    Connecting & Using Flash Heads   

6

    Modelling Options & Synchronisation    7

    Ready Indication & IR Remote Control   8

    Speed Control & Test Function 

9

    Flash Before Ready, Fan Cooling and 
    Protection System and Faults 

10

    Technical Specifications 

 

11

Summary of Contents for CREO 1200

Page 1: ...Owner s Handbook...

Page 2: ...judged to have experienced any of the following points failure to follow working instructions correctly accidental or willful damage misuse alteration or repair by a non authorised Bowens service repa...

Page 3: ...ch turn power OFF before before fitting or removing any flash heads Avoid placing cables where they can be tripped over Protect from heavy sharp or hot objects which may cause damage and replace damag...

Page 4: ...ling Mode Button PG 7 I Flash Open Test Button PG 9 J Mains AC Power Connection K Radio Trigger Card Slot PG 7 L Channel B Socket M Channel B LED Display N Power On Off Button O Channel B 1 Stop Power...

Page 5: ...ators 2 Channel A Power Adjust 3 Modelling On Off 4 Ready Indications 5 Channel Select 6 Channel B Power Adjust 7 Modelling Mode 8 Sync Options 9 Flash Open Test A Accessory Release Latch B Flash Tube...

Page 6: ...us beep until the flash power adjust button is released The generator will not alter the actual power level setting until a short period after the user has stopped changing the setting this is to avoi...

Page 7: ...ach channel will be displayed on the appropriate channel LED displays The modelling output setting for each channel can then be adjusted independently by using the STOPS and TENTHS buttons regardless...

Page 8: ...dicate a button press Because of the fast recharging capabilities of the Creo the lamps may appear to not dim with low flash power settings NB The dim ready indication will only be enabled if the mode...

Page 9: ...ycling speed 25 is approximately four times as long as the fastest 100 recycling speed This option should be selected when the Creo is connected to a mains power supply with weak fuses or inadequate s...

Page 10: ...und and removed OVERHEAT if the charge limiter fails to prevent the temperature rising then the recharging will stop completely This will be indicated by OH on both channel LED displays The generator...

Page 11: ...0 4 0 80K Colour Stability Energy Range 10 0 2 0 175K Creo 2400 Rated Energy F10 2400Ws Input Power Supply 100 127V 200 240V 50 60Hz Automatic Multi Voltage Yes use appropriately rated modelling lamp...

Page 12: ...O 2400 BW 9000 CREO FLASH HEAD BW 7760 FLASH TUBE CLEAR BW 3019 MODELLING LAMP 230V 650W BW2503 300W BW2504 MODELLING LAMP 117V 300W BW7515 GLASS DOME UV COATED BW 2981 GLASS DOME CLEAR BW 2982 GLASS...