Bowens CREO 1200 Owner'S Handbook Manual Download Page 6

One  or  two  compatible  flash  heads  may  be 
connected to a Creo generator. Always switch the 
generator to ‘standby’ when fitting or removing any 
flash  heads.  When  connecting  a  flash  head  to  a 
Creo pack always ensure that the head connectors 
are  fully  engaged  with  the  locking  clips  before 
turning the generator ‘on’.

When a flash head is not fully connected/fitted, the 
associated channel LED display will show ‘- -’.

When a flash head is connected fully the appropriate 
channel  LED  display  shows  the  selected  flash 
power setting in f-stops.

flash

 

power

 

control

The flash power adjust buttons are used to control 
the  power  output  for  the  associated  flash  head 
fitted to a particular channel. A single press of either 
1-Stop or 1/10-Stop flash power adjust button will 
adjust  the  output  by  a  single  increment;  the  flash 
power  adjustment  will  be  confirmed  by  a  single 
short beep (if the sounder is enabled). 

By  pressing  and  holding  a  flash  power  adjust 
button, the generator will adjust the flash power at 

an increased rate; every increment adjustment will 
be confirmed by a single short beep (if the sounder 
is  enabled).  At  the  end  of  the  achievable  power 
range  the  generator  will  emit  a  long  continuous 
beep until the flash power adjust button is released.

The generator will not alter the actual power level 
setting  until  a  short  period  after  the  user  has 
stopped  changing  the  setting;  this  is  to  avoid 
unnecessary dumping/charging of the flash power.

To manually dump an excess flash power press the 
‘flash/open test button’.

•   The 

STOPS +/- buttons will adjust the flash

      power  by 1-Stop steps until the end of the 
      achievable flash power range is reached.

•   The 

TENTHS +/- buttons will adjust the flash 

      power by 1/10-Stop steps until the end of the 
      achievable range is reached.

The  maximum  flash  power  available  from  each 
head is dependant on the number of channels used 
and  the  flash  power  setting  of  each  channel  (see 
tables opposite for max power settings).

When  two  heads  are  fitted  and  more  power  is 
required from a particular channel than is currently 

available,  then  the  setting  of  the  other  head  must 
be  decreased  i.e.  when  using  a  Creo  2400Ws,  if 
channel  A  is  set  to  9.7  then  the  range  of  channel 
B is 1.0 to 6.5. By lowering the setting of channel 
A to 9.4 then the power range of channel B will be 
extended from 1.0 to 8.2.

connecting and using flash heads

6

 - Cr

eo | 

connecting and using flash heads

CREO 1200

Channel A Max

Channel B Max

10.0

Head Not Fitted

9.7

6.5

9.4

8.2

9.0

9.0

CREO 2400

Channel A Max

Channel B Max

10.0

Head Not Fitted

9.8

5.5

9.7

7.2

9.5

8.0

9.4

8.4

9.2

8.7

9.0

9.0

Summary of Contents for CREO 1200

Page 1: ...Owner s Handbook...

Page 2: ...judged to have experienced any of the following points failure to follow working instructions correctly accidental or willful damage misuse alteration or repair by a non authorised Bowens service repa...

Page 3: ...ch turn power OFF before before fitting or removing any flash heads Avoid placing cables where they can be tripped over Protect from heavy sharp or hot objects which may cause damage and replace damag...

Page 4: ...ling Mode Button PG 7 I Flash Open Test Button PG 9 J Mains AC Power Connection K Radio Trigger Card Slot PG 7 L Channel B Socket M Channel B LED Display N Power On Off Button O Channel B 1 Stop Power...

Page 5: ...ators 2 Channel A Power Adjust 3 Modelling On Off 4 Ready Indications 5 Channel Select 6 Channel B Power Adjust 7 Modelling Mode 8 Sync Options 9 Flash Open Test A Accessory Release Latch B Flash Tube...

Page 6: ...us beep until the flash power adjust button is released The generator will not alter the actual power level setting until a short period after the user has stopped changing the setting this is to avoi...

Page 7: ...ach channel will be displayed on the appropriate channel LED displays The modelling output setting for each channel can then be adjusted independently by using the STOPS and TENTHS buttons regardless...

Page 8: ...dicate a button press Because of the fast recharging capabilities of the Creo the lamps may appear to not dim with low flash power settings NB The dim ready indication will only be enabled if the mode...

Page 9: ...ycling speed 25 is approximately four times as long as the fastest 100 recycling speed This option should be selected when the Creo is connected to a mains power supply with weak fuses or inadequate s...

Page 10: ...und and removed OVERHEAT if the charge limiter fails to prevent the temperature rising then the recharging will stop completely This will be indicated by OH on both channel LED displays The generator...

Page 11: ...0 4 0 80K Colour Stability Energy Range 10 0 2 0 175K Creo 2400 Rated Energy F10 2400Ws Input Power Supply 100 127V 200 240V 50 60Hz Automatic Multi Voltage Yes use appropriately rated modelling lamp...

Page 12: ...O 2400 BW 9000 CREO FLASH HEAD BW 7760 FLASH TUBE CLEAR BW 3019 MODELLING LAMP 230V 650W BW2503 300W BW2504 MODELLING LAMP 117V 300W BW7515 GLASS DOME UV COATED BW 2981 GLASS DOME CLEAR BW 2982 GLASS...

Reviews: