40
10. Setting and optimal operating values
General data:
P 300 USA
P 350 USA
Steam pressure (saturated steam)
psi
58-72.5
58-72.5
Steam temperature (max. permissible)
°F
302
302
Cooling water pressure
psi
29-58
29-58
Max. cooling water temperature
°F
77
77
Compressed air
psi
87
87
Cleaning speed
rpm
40
40
Extraction speed
rpm
375
375
Reversing cycle
sec.
10 -5 - 10
10 - 5 - 10
Low level
US gal
7.9
9.2
High level
US gal
15.9
18.5
Max. pump pressure
psi
36.3
36.3
Filter surface ECO-filter ft
2
25.8
25.8
Precoat-powder (option only on machines
without emissionfree still rake out system)
lb
2.6
2.6
Tank I: min. filling volume
US gal
15.9
18.5
Refrigeration technique:
Filling quantity cooling agent R 404A
lb
7.7
11.0
Expansion valve Danfoss TES2
°F
+ 50 to -40
+ 50 to -40
Nozzle sizes:
Solvent cooling
No.
3
3
Drying
No.
4
4
High pressure control switch ON
psi
319
319
High pressure control switch OFF
psi
377
377
Solvent cooling:
Temp.-sensor batch:
Solvent cooling ON
°F
59-86
59-86
Drying:
Cooling water regulator:
setting 4 - 6 min. after start drying
psi
319
319
Temp.-sensor cage exit:
°F
122
122
Temp.-sensor after cooler:
Control temp. drying
°F
104
104
Control temp. cycle end
°F
59
59
Safety Temp.-sensor heater (only electr.)
°F
194
194
Distillation:
Cooling water regulator condenser
°F
113
113
Temp.-sensor:
Cycle distillation OFF
°F
275
275
Still stripping OFF
°F
280 /293 (el)
280 /293 (el)
Temp.-sensor distilled solvent
°F
131
131
Bore diameter in the reduction of the steam piping
inch
0.16
0.16
Bore diameter in the reduction in direct steam piping
inch
0.12
0.12
Water filling quantity in heating chamber approx.
US gal
1.3
1.3
Still pressure control switch (only electr.)
ON
psi
75.4
75.4
OFF
psi
81.2
81.2
Attention:
No cooling againt should excape into the atmosphere from
the refrigeration unit, when working, during maintenance, or when
disposing of the unit. The amount of refrigeration agent used must
be registered and if desired shown to the competent authorities.
Maintenance work and the disposal of refrigeration units should
only be carried out by persons who have the required experience
and technical equipment.
!