17
6. Installation
6.2.2
Machine dimensions
Slimline
Crossline
P 240 /P 300
P 240 /P 300
P 300 USA /P 350 USA
P 300 USA /P 350 USA
_______________________________________________________________________________
Width
mm 1080
inch 42.5
mm 1840
inch 72.4
Depth
mm 2140
inch 84.2
mm 1365
inch 53.7
Height without cool-down flap
mm 2105
inch 82.9
mm 2105
inch 82.9
Height with cool-down flap
mm 2300
inch 90.6
mm 2300
inch 90.6
6.3
Floor load
The place of installation must conform to the floor load which is composed of:
-
static load = machine max. solvent filling and
-
dynamic load = centrifugal cage force with normally
distributed, extraction-damp garments.
The force created during extraction must also be taken into account
(floor, supporting walls etc.). Resonances are not permissible.
Please consult building specialists.
6.3.1
Dimensions
Slimline
Crossline
P 240 /P 300
P 240 /P 300
P 300 USA /P 350 USA
P 300 USA /P 350 USA
________________________________________________________________________
Depth*
mm (inch) 1200 (47.2) 1310 (51.6)
1200 (47.2)
1310 (51.6)
Width*
mm (inch) 1080 (42.5) 1080 (42.5)
1080 (42.5)
1080 (42.5)
Portion of the floor surface
for the force transmission
m² (sq.ft.)
1.3 (14) 1.41 (15.2)
1.3 (14)
1.41 (15.2)
Weight without solvent
kg (lb)
980 (38.6) 1080 (42.5)
1080 (42.5)
1100 (43.3)
Weight with solvent
(stat. load)
kg (lb)
1300 (51.2) 1470 (57.9)
1400 (55.1)
1490 (58.7)
Centrifugal cage force
(dyn. load)
N
4800
6000
4800
6000
Floor load (stat. + dyn. load)
- Standard drive
N/m²
13600
14500
14300
14600
*Portion of the complete machine dimension, that is decisive
for the floor load and the centrifugal cage force.
Regarding the foundation work please consult building experts.
They will take machine-related as well as local particulars into account
and find the best solution.
Please use a load dispatcher frame if the permissible floor load is inadequate.