20
7. Connection
7.2
Machine connections specification
Slimline
703868-16-A
We reserve the right to change measurements!
Pos.
Medium
NW
Zoll
- X -
- X -
- Y -
- Y -
mm
inch
mm
inch
mm
inch
________________________________________________________________________
1
Steam still
15
1/2
610
24
950
37.4
2
Condensate still
15
1/2
775
30.5
190
7.5
3
Condensate heater
15
1/2
220
8.7
1400
55.1
4
Steam heater
15
1/2
90
3.5
1440
56.7
5
Cooling water inlet without tank cooling 15
1/2
660
26
1220
48
6
Cooling water inlet with tank cooling
15
1/2
480
18.9
90
3.5
7
Cooling water inlet still electr.
with water addition
15
1/2
660
26
440
17.3
8
Cooling water outlet
20
3/4
70
2,8
1650
65
9
Compressed air
8
1/4
840
33.1
1400
55.1
10
Electr. connection
130
5.1
1480
58.3
11
Venting water separator
22
-
740
29.1
1360
53.5
12
Rake out system - pump out
20
3/4
740
29.1
1020
40.2