Climatic and mechanical class
C
Electromagnetic class
E1
Mechanical class
M1
2.2 Calculator
The calculator is a device that calculates the flow volume consumed based on signals from
flow sensor. It
’
s also the control, display and data store part for the meter.
Calculator specification:
Manufacturer
Bove
Climatic and mechanical class
C
Electromagnetic Class
E1
Mechanical Class
M1
Display unit
M
3
, L
Battery power supply requirements
See part: 4 Power supply
Pulse input device class
N/A
Max permissible flow sensor signal(Pulse
rate)
N/A
Output signal for normal operation
M-Bus, Infrared, RS485, LoRa
Pulse output device class
N/A
Output signal for testing
M-Bus, Infrared, RS485, LoRa
Liquid if other than water
N/A
2.3 Completer meter
Manufacturer
Bove
Flow Measurement
DN
(mm)
Flow Rate (m
3
/h)
Dimensions (mm)
Connection
Q1
Q2
Q3
Q4
Length
Height
D1
D2
Bolt (flange)
50
0.125
0.2
25
31.25
200
245
125
165
4*M16
65
0.5
0.32
40
50
200
260
145
185
4*M16
80
0.315
0.504
63
78.75
225
285
160
200
8*M16
100
0.5
0.8
100
125
250
295
180
220
8*M16
125
0.8
1.28
160
200
250
305
210
250