1. General Information
Please note that the following installation conditions must be obeyed:
Pressure Requirement: MAP16.
Environmental Class: E1, M1
Installation requirement: There must be a distance of minimum 25 cm between signal
cables and other installations
If medium temperature is below 10
°
C or above 90
°
C in flow sensor, It
’
s recommended
that the calculator be wall-mounted.
Note: Seal or any safety marks on the meter must not be damaged or removed, and doing so
will void the warranty and calibration of the meter.
2. Technical Specification
2.1 Flow Sensor
The flow sensor is a device used to measure the velocity of flow by using the principle of
ultrasound. It can measure the average velocity along the path of an emitted beam of
ultrasound by averaging the difference in measured transit time between the pulses of
ultrasound propagating into and against the direction of the flow. The flow measurement is
based on an acoustic wave time of flight principle. The flow meter body is equipped with 2
ultrasonic transducers facing 2 acoustic reflectors.
Flow sensor data:
Manufacturer
Bove
Type
B39 VW
Accuracy class
Class 2
MAP
10 bar
Max Pressure loss at Q3
≤63kPa
Max admissible temperature
50°C
Limits of temperature (Θ
min
and Θ
max
)
0.1-30°C,0.1-50°C
Installation requirements
Min. 10*DN length of straight pipe before the
meter, and Min. 5*DN length of straight pipe after
the meter (DN is the diameter of meter)
Basic mounting orientation and other
specified orientations
Horizontal/Vertical
Output signal for testing
Analog signal 1Mhz
power supply
Lithium Battery
Current used
Average 20uA, Peak 4mA