Bove Technology B39 VW Bulk Installation & User Manual Download Page 13

 

 

Copyright© 2018 Bove Intelligent Technology Co., Ltd 

10 / 17 

standard. In addition, one of the following options can be ordered for remote output.   

5.2 M-BUS 

Cable: connected with galvanic isolation 
Voltage: 50V max.   
Current: M-Bus loads   
Addressing: primary or secondary   
Note: A higher frequency is not allowed and may result in meter malfunction!   
Data transmission in the compatibility mode (= standard, one data frame) or in the full mode 
(3 data frames) possible.   
If the meter is equipped with 

M-bus

, it is delivered with a two wire cable, which can be 

lengthened with a cable 2 x 0.75mm2 (put a distributing box). Pay attention to the proper 
polarity  in case  of the  pulse  output. If the meter is read  out  via  M-bus, the  allowed  mean 
frequency  of  reading  must  not  be  exceeded.  Any  more  reading  is  not  allowed  and  may 
result in a damage to meter.   
The  M-Bus  or  pulse  variant  of  the  meter  is  supplied  with  a  2-wire  cable  with  wire  end 
ferrules. 

Version/Color 

Pulse 

M-Bus (2-wire) 

Red 

Pulse 

M-Bus 

Black 

GND 

M-Bus 

5.3 Pulse Output (Optional) 

Pulse output for heat or volume, with 2m cable connected, with galvanic isolation   
Pulse significance: 1 pulse per 100/1000 liter   
Pulse length: 100 ms (Programmable) 
Heat / Volume: specify in order or change with service-software   
Voltage: max. 30 V   
Current: max. 30 mA   
Pulse break: min. 25ms 
Classification OC (acc. to EN 1434-2)   
Voltage drop: ca. 1.3V at 20 mA 
 

5.4 RS-485(Optional) 

Cable: connected with four-core cable 
Voltage: 5-24V.   

Version/Color 

RS-485 

Red 

VCC 

Summary of Contents for B39 VW Bulk

Page 1: ...www bovetech com Installation User Guide B39 VW Bulk Ultrasonic Water Meter Read this Guide before installing the meter...

Page 2: ...f this manual to ensure the accuracy of its contents However should you have any questions or find any errors please contact BOVE TECHNOLOGY Copying or reproducing all or any part of the contents of t...

Page 3: ...EQUIREMENTS FOR INSTALLATION ENVIRONMENT 5 3 2 INSTALLATION SPECIFICATION 6 3 3 BEFORE INSTALLATION 6 3 4 COMMON ERROR INSTALLATION EXAMPLES 7 3 5 INSTALLATION OF NON RETURN VALVE 9 3 6 AFTER THE INST...

Page 4: ...asure the average velocity along the path of an emitted beam of ultrasound by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direct...

Page 5: ...wer supply requirements See part 4 Power supply Pulse input device class N A Max permissible flow sensor signal Pulse rate N A Output signal for normal operation M Bus Infrared RS485 LoRa Pulse output...

Page 6: ...rror in upper flow rates range Q2 Q Q4 2 at 30 C 3 at 30 C Maximum permissible error in lower flow rates range Q1 Q Q2 5 Scale interval m3 0 01 Capacity of calculator 99999 99 999 Type of liquid Water...

Page 7: ...ply Battery One 3 6V Lithium Battery Battery Life 6 Years 24V DC External supply for special version Optional Mechanical Specification Meter body Cast steel 2 4 Data Storage 1 Accumulated flow for the...

Page 8: ...ng term submergence provided that all cable unions have been correctly mounted and that the plastic cover has been properly fastened Make sure the meter is installed sufficiently far away from possibl...

Page 9: ...onic water meter should pay special attention The water meter should be avoided to be installed at the upper end of the pipeline there will be bubbles in the pipe avoiding installation near the elbow...

Page 10: ...ontally the direction of the calculator should be upwards If the direction of the calculator is facing to the side the two transducers will not be on one level and the transducer at the high point may...

Page 11: ...meter is installed at the elbow it must be ensured that the distance between the front straight pipe is 5 pipe diameter and the rear straight pipe is 3 pipe diameter Otherwise the meter may not be mea...

Page 12: ...splay information When the response thresholds are exceeded and the flow rate is positive the volume is summated Make the segment test in order to displays all display segments for test purposes The o...

Page 13: ...rity in case of the pulse output If the meter is read out via M bus the allowed mean frequency of reading must not be exceeded Any more reading is not allowed and may result in a damage to meter The M...

Page 14: ...may press the button to read the meter information such as Accumulated volume current flow rate etc The following information is displayed in order by short pressing the button accumulated flow insta...

Page 15: ...Copyright 2018 Bove Intelligent Technology Co Ltd 12 17 6 1 2 Main Menu Shortly pressing the button to display items under the Main Menu one by one in the following order to check the measurement data...

Page 16: ...Copyright 2018 Bove Intelligent Technology Co Ltd 13 17 6 1 3 Menu E Shortly pressing the button to display items under Menu E one by one in the following order to check the meter information...

Page 17: ...8 Bove Intelligent Technology Co Ltd 14 17 6 1 4 Menu I This Menu shows history date records of last 24 months Click the button to select the month then the month monthly flow consumption will be disp...

Page 18: ...cally when flow is zero and starts to exceed the preset value then the current accumulated value is clear to zero Also the value can be reset by long pressing the button over 2 seconds The meter exit...

Page 19: ...elf diagnosis and can display various faults Visual indication on the LCD display in the event of an warning Permanent visual indication on the LCD Fault Meaning How to handle the error 1 Low battery...

Page 20: ...rompt services and reliable products to our global customers Bove is committed to address the unique challenges that the residential and industry are facing including increasing customer demand water...

Reviews: