Bove Technology B39 VW Bulk Installation & User Manual Download Page 19

 

 

Copyright© 2018 Bove Intelligent Technology Co., Ltd 

16 / 17 

6.2 Monthly Data 

The calculator stores the following values for 24 months at each end of month   
- Volume (meter reading)   
From  the  month  set  day  display,  press  the  button  shortly  to  enter  the  previous  month's 
values.   
The month values can also be read out via the optical interface and other communication 
ports. 

7. Error and Warning 

The  meter  constantly  performs  self-diagnosis  and  can  display  various  faults.  Visual 
indication on the LCD display in the event of an warning. Permanent visual indication on the 
LCD: 

Fault 

Meaning 

How to handle the error 

Low battery 

Communication circuit to be checked 

Empty Pipe 

Fulfill the pipe with water, no air bubble. 

Reverse Flow 

Reverse the water pipe. 

Over Range (High Instant flow rate) 

Lower the instant flow rate, or change a higher 

Range water meter. 

Water Temperature Error 

Lower the water temperature 

EE Memory Error 

Change circuit board. 

Flow Sensor Error (water-in) 

Change sensor 

Flow Sensor Error (water-out) 

Change sensor 

 
 
 

Summary of Contents for B39 VW Bulk

Page 1: ...www bovetech com Installation User Guide B39 VW Bulk Ultrasonic Water Meter Read this Guide before installing the meter...

Page 2: ...f this manual to ensure the accuracy of its contents However should you have any questions or find any errors please contact BOVE TECHNOLOGY Copying or reproducing all or any part of the contents of t...

Page 3: ...EQUIREMENTS FOR INSTALLATION ENVIRONMENT 5 3 2 INSTALLATION SPECIFICATION 6 3 3 BEFORE INSTALLATION 6 3 4 COMMON ERROR INSTALLATION EXAMPLES 7 3 5 INSTALLATION OF NON RETURN VALVE 9 3 6 AFTER THE INST...

Page 4: ...asure the average velocity along the path of an emitted beam of ultrasound by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direct...

Page 5: ...wer supply requirements See part 4 Power supply Pulse input device class N A Max permissible flow sensor signal Pulse rate N A Output signal for normal operation M Bus Infrared RS485 LoRa Pulse output...

Page 6: ...rror in upper flow rates range Q2 Q Q4 2 at 30 C 3 at 30 C Maximum permissible error in lower flow rates range Q1 Q Q2 5 Scale interval m3 0 01 Capacity of calculator 99999 99 999 Type of liquid Water...

Page 7: ...ply Battery One 3 6V Lithium Battery Battery Life 6 Years 24V DC External supply for special version Optional Mechanical Specification Meter body Cast steel 2 4 Data Storage 1 Accumulated flow for the...

Page 8: ...ng term submergence provided that all cable unions have been correctly mounted and that the plastic cover has been properly fastened Make sure the meter is installed sufficiently far away from possibl...

Page 9: ...onic water meter should pay special attention The water meter should be avoided to be installed at the upper end of the pipeline there will be bubbles in the pipe avoiding installation near the elbow...

Page 10: ...ontally the direction of the calculator should be upwards If the direction of the calculator is facing to the side the two transducers will not be on one level and the transducer at the high point may...

Page 11: ...meter is installed at the elbow it must be ensured that the distance between the front straight pipe is 5 pipe diameter and the rear straight pipe is 3 pipe diameter Otherwise the meter may not be mea...

Page 12: ...splay information When the response thresholds are exceeded and the flow rate is positive the volume is summated Make the segment test in order to displays all display segments for test purposes The o...

Page 13: ...rity in case of the pulse output If the meter is read out via M bus the allowed mean frequency of reading must not be exceeded Any more reading is not allowed and may result in a damage to meter The M...

Page 14: ...may press the button to read the meter information such as Accumulated volume current flow rate etc The following information is displayed in order by short pressing the button accumulated flow insta...

Page 15: ...Copyright 2018 Bove Intelligent Technology Co Ltd 12 17 6 1 2 Main Menu Shortly pressing the button to display items under the Main Menu one by one in the following order to check the measurement data...

Page 16: ...Copyright 2018 Bove Intelligent Technology Co Ltd 13 17 6 1 3 Menu E Shortly pressing the button to display items under Menu E one by one in the following order to check the meter information...

Page 17: ...8 Bove Intelligent Technology Co Ltd 14 17 6 1 4 Menu I This Menu shows history date records of last 24 months Click the button to select the month then the month monthly flow consumption will be disp...

Page 18: ...cally when flow is zero and starts to exceed the preset value then the current accumulated value is clear to zero Also the value can be reset by long pressing the button over 2 seconds The meter exit...

Page 19: ...elf diagnosis and can display various faults Visual indication on the LCD display in the event of an warning Permanent visual indication on the LCD Fault Meaning How to handle the error 1 Low battery...

Page 20: ...rompt services and reliable products to our global customers Bove is committed to address the unique challenges that the residential and industry are facing including increasing customer demand water...

Reviews: