20
Doc M-PR-09-45.120119.1
SapCheck User’s Guide
The Bos
w
orth Company
L
C
(
’
)
Text Message Command
Meaning
set calibrate hivac
<##.#>
Sets the high vacuum endpoint used for calibra ng
the SapCheck vacuum sensor. Usually, this is cho
‐
sen when the system is running at or near the high
‐
est vacuum as indicated by a second, calibra ng
gauge. The value entered for <
##.#
> is the value
(in units of in Hg) reported by the second, cali
‐
bra ng gauge.
set report
<value>
Sets the me interval in hours at which SapCheck
will automa cally send status message texts. Use
‐
ful if you want to see status informa on on a regu
‐
lar basis without having to issue “?status” text
messages for each report.
set temp o
ff
<value>
OR
=temp o
ff
<value>
Sets the "falling" temperature value when the
pump will turn o
ff
under auto
‐
temp control. If the
temperature is already below this temperature, the
pump will turn o
ff
if under auto
‐
temp control.
set temp on <value>
OR
=temp on
<value>
Sets the "rising" temperature value when the
pump will turn on under auto
‐
temp control. If the
temperature is already above this temperature, the
pump will turn on if under auto
‐
temp control.
set calibrate
Installs the “lowvac” and “hivac” points speci
fi
ed
by the set calibrate lowvac and hivac commands
and automa cally reboots SapCheck. Vacuum
sensor re
‐
calibra on will take e
ff
ect when Sap
‐
Check restarts.
set user
<xxxyyyzzzz>
Example:
set user 4011234567
will allow that phone # to
issue SapCheck commands
and receive SapCheck mes
‐
sages
Sets the user phone # (area code + number; no
dashes!) which the unit will recognize as a
"command
‐
generating" number.
IMPORTANT!
Be
very
careful
using
this
command.
If
you
do
not
enter
the
phone
#
correctly,
you
may
enable
command
of
your
SapCheck
unit
by
an
un-
known
party!
set user <xxxyyyzzzz> del
Deletes phone # xxxyyyzzzz from the command
number list.