8. Drill a 9/32” hole in the pump enclosure box near where the SapCheck
Controller is located and pass the temperature sensor (
E
) from inside the
enclosure to the outside. (See Figure 7.) Ensure that the end of the
temperature sensor probe is exposed to the outside temperature.
Figure 7b
Figure 7a
Figure 7c
11
Doc M-PR-09-45.120119.1
The Bos
w
orth Company
SapCheck User’s Guide
Figure 6a
Figure 6b
Figure 6c
Figure 6d
(6a) Remove red nut from one of the Posi
‐
tab terminals on the 12’
fl
oat switch
cable and insert one of the bared end
fl
oat switch wires through the red nut. (6b)
Insert the bared end wire into the other end of the Posi
‐
tab terminals. Screw the
red nut from (6a) onto the Posi
‐
tab terminal in (6b) into which the
fl
oat switch
wire has been inserted. When the red nut is completely screwed onto the Posi
‐
tab terminal, pull on the
fl
oat switch wire (6d) to test that a solid connec on has
been made. Repeat to connect the other
fl
oat switch wire to the remaining
fl
oat
(7a) shows temperature probe being inserted through 9/32” diameter hole in
fl
oor
of pump enclosure box. (7b) shows temperature sensor installed through a hole
in the
fl
oor of the pump enclosure box. (7c) shows the metal end of the tempera
‐
ture probe located outside and below the pump enclosure box. The metal end p
of temperature sensor must be exposed to the outside air to correctly register
outside temperature. The probe p should be located at least 12 inches away
from the pump enclosure box so that it does not register heat being radiated in
the area immediately near the box by the equipment opera ng within.
9/32” diameter