Section 3 • Systems & Components Overview & Operation
R
Your 280 Outrage is equipped with two (2) bilge
pumps. The forward pump is rated at 750 GPH
(2,839 LPH) and located in the aft floor of the console
and can be accessed by lifting the grate in the floor.
The aft pump is rated at 1,100 GPH (4,164 LPH).
The aft pump is located in the bilge and can be
accessed by lifting the floor hatch in the aft cockpit.
Each pump is activated automatically by a mercury
free float switch when the water in the bilge reaches
a predetermined level.
If equipped there is an auxiliary pump rated at 1,100
GPH (4,164 LPH) located in the bilge along with
the aft pump.
Switches on the console switch panel labeled FWD
BILGE, AFT BILGE & AUX BILGE ( See figure
2.19.1) control the operation of the pumps. The
switches should remain in the AUTO position
while in use, unless the operator wishes to manually
operate the pumps by depressing the switch to the
ON position.
Bilge Pumps
The bilge pumps discharge water overboard by way
of thru-hull fittings (See figure 2.7.1).
Fuel & Oil Spillage
Regulations prohibit discharging fuel or oily waste in
navigable waters. Discharge is defined as any action
which causes a film, sheen or discoloration on the
water surface, or causes a sludge or emulsion beneath
the water surface. A common violation is bilge
discharge. Violators are subject to severe penalties
and may also be responsible for the cost of cleanup
which may be substantial.
Use rags or sponges to soak up fuel or oily waste,
then dispose of them properly ashore. If there is a
large quantity of fuel or oil in the bilge, contact a
knowledgeable marine service to remove it.
Never
pump contaminated bilge discharge overboard.
Maintenance
The aft pump can be accessed through the hatch in
aft cockpit. Access the forward pump by lifting the
grate in the aft floor of the console.
Frequently inspect the area under the float switches
to ensure they are free from debris and gummy
bilge oil. To clean, soak in heavy duty bilge cleaner
for 10 minutes, agitating several times. Check
for unrestricted operation of the float. Repeat the
cleaning procedure if necessary.
Aft Bilge Pump
Fig. 3.1.1
1
2
3
AFT BILGE PUMP (1,100 GPH/4164 LPH)
WATER INLET
LOCKING TABS
DISCHARGE
FORWARD BILGE PUMP (1,100 GPH/4164 LPH)
4
Forward Bilge Pump
Fig. 3.1.2
1
2
FORWARD BILGE PUMP (750 GPH/2,839LPH)
VACU-FLUSH
®
TOILET
1
2
1
2
3
4
5
5
Summary of Contents for 280 Outrage
Page 1: ...2 8 0O u t r a g e O w n e r sMa n u a l ...
Page 19: ...xviii 280 Outrage R THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 43: ...1 24 280 Outrage Section 1 Safety R THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 73: ...2 30 280 Outrage Section 2 General Information R THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 111: ...4 8 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 1 Fig 4 8 1 ...
Page 112: ...4 9 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 2 Fig 4 9 1 ...
Page 113: ...4 10 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 3 Fig 4 10 1 ...
Page 114: ...4 11 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 4 Fig 4 11 1 ...
Page 115: ...4 12 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 5 Fig 4 12 1 ...
Page 116: ...4 13 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 6 Fig 4 13 1 ...
Page 117: ...4 14 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 7 Fig 4 14 1 ...
Page 118: ...4 15 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 8 Fig 4 15 1 ...
Page 119: ...4 16 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 9 Fig 4 16 1 ...
Page 120: ...4 17 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 10 Fig 4 17 1 ...
Page 121: ...4 18 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 11 Fig 4 18 1 ...
Page 122: ...4 19 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 12 Fig 4 19 1 ...
Page 123: ...4 20 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 13 Fig 4 20 1 ...
Page 124: ...4 21 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 14 Fig 4 21 1 ...
Page 125: ...4 22 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 15 Fig 4 22 1 ...
Page 126: ...4 23 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 16 Fig 4 23 1 ...
Page 127: ...4 24 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 17 Fig 4 24 1 ...
Page 128: ...4 25 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 18 Fig 4 25 1 ...
Page 129: ...4 26 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 19 Fig 4 26 1 ...
Page 130: ...4 27 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 20 Fig 4 27 1 ...
Page 131: ...4 28 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 21 Fig 4 28 1 ...
Page 132: ...4 29 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 22 Fig 4 29 1 ...
Page 133: ...4 30 280 Outrage Section 4 Electrical System R 280 OR Wiring Sheet 23 Fig 4 30 1 ...
Page 134: ...4 31 280 Outrage Section 4 Electrical System R NAUTIC ON Sheet 1 Fig 4 31 1 ...
Page 135: ...4 32 280 Outrage Section 4 Electrical System R NAUTIC ON Sheet 2 Fig 4 32 1 ...
Page 136: ...4 33 280 Outrage Section 4 Electrical System R NAUTIC ON Sheet 3 Fig 4 33 1 ...
Page 137: ...4 34 280 Outrage Section 4 Electrical System R NAUTIC ON Sheet 4 Fig 4 34 1 ...
Page 138: ...4 35 280 Outrage Section 4 Electrical System R NAUTIC ON Sheet 5 Fig 4 35 1 ...
Page 139: ...4 36 280 Outrage Section 4 Electrical System R Battery Harness Fig 4 36 1 BATTERY SET ...
Page 141: ...4 38 280 Outrage Section 4 Electrical System R Console Harness Fig 4 38 1 ...
Page 142: ...4 39 280 Outrage Section 4 Electrical System R Hardtop Harness Fig 4 39 1 ...
Page 143: ...4 40 280 Outrage Section 4 Electrical System R Leaning Post Harness Fig 4 40 1 ...
Page 146: ...4 43 280 Outrage Section 4 Electrical System R T Top Harness Fig 4 43 1 T TOP HARNESS ...
Page 147: ...4 44 280 Outrage Section 4 Electrical System R Windlass Harness Fig 4 44 1 WINDLASS HARNESS ...
Page 161: ...5 14 Section 5 Care Maintenance R 280 Outrage THIS PAGE INTENTIONALLY LEFT BLANK ...