4-8
Section 4
Boat Systems
Bilge Pump System
Your bilge pump system consists of a forward
1100
gallon per hour (GPH) pump and an aft 1100 GPH
pump. Each bilge pump is connected to a water level
sensor that will automatically activate the system
when water in the bilge reaches a depth of about two
inches.
One 1100 GPH pump is located in the bilge, just for-
ward of the control console. It is under a removable
sump cover. The discharge for the forward bilge pump
is located midship on the starboard side.
One 1100 GPH pump is located in the aft bilge area
and can be accessed through a deck hatch. This
pump discharges on the starboard side just forward of
the transom.
The bilge pump power circuit is wired directly to the
battery side of the
port
engine battery OFF-ON switch.
The bilge pump system has an uninterruptible power
supply that is not affected by the position of the port
engine battery OFF-ON switch.
The uninterruptible bilge pump power circuit is pro-
tected by a 20-amp blade fuse. The fuse is located in
a water-proof holder that is within seven inches of the
port engine battery OFF-ON switch.
Summary of Contents for 25 Guardian Series
Page 18: ...1 10 Section 1 Safety Deck Occupancy Chart ...
Page 20: ...1 12 Section 1 Safety Warning Label Chart 1 3 4 5 6 7 8 9 6 0 A D E H C F G 2 B ...
Page 22: ...1 14 Operator Notes ...
Page 52: ...2 30 Operator Notes ...
Page 56: ...3 4 Section 3 Fuel Systems Fuel System Diagram 1 2 3 5 7 9 A C 0 B 4 6 8 ...
Page 68: ...3 16 Operator Notes ...
Page 70: ...4 2 Section 4 Boat Systems Control Console Layout 1 0 2 4 6 8 9 3 5 7 A B D F H J K C E G I L ...
Page 92: ...4 24 Operator Notes ...
Page 99: ...5 7 Operator Notes ...
Page 120: ...6 12 Section 6 Boat Maintenance Trailer Setup ...
Page 132: ...6 24 Operator Notes ...