background image

17

4.6 PROGRAM OPTIONS AND EDITING
4.6.1 SEQUENCE NUMBER (SL)

There are 5 programmable screw fastening sequences (SL = ‘U1’ to ‘U5’) available. In many cases, only the 
first sequence (U1) will be needed. If the screwdriver is used to install a batch of fasteners with varying 
requirements, multiple sequences may be necessary. For example, if an assembly requires the installation 
of 4 screws, where 3 screws are short, and 1 screw is long, the controller can be programmed with 2 
unique sequences - a sequence for the short screws and one for the long screws. This would allow different 
time windows to be set-up for the two difference screw lengths. Each sequence must be programmed 
separately, and numbered in the order that the screws will be installed (starting with sequence U1). In this 
example, if the 3 short screws are to be installed first, enter the program for sequence ‘U1’ with a batch 
quantity of 3 and time parameters for the short screw. Then repeat the program steps for sequence ‘U2’ 
with a batch quantity of 1 and the time parameters for the long screw. Finally, program sequence ‘U3’ with 
a batch quantity of ‘00’ to signify that there are no further fasteners to install.
(For multiple sequences, refer also to info on setting dip switch #6 later on in this manual)

4.6.2 BATCH COUNT SETTING (SC)

Enter the desired number of fasteners to be installed per batch. Depending on the setting of DIP switch #1, 
the display will either count down from the total batch value entered, or count up to the total batch value. 
The count will only increment (and indicate ‘GOOD’ rundown) if the rundown cycle falls within the limits set 
by the min and max rundown time settings (see below). When all fasteners in the batch have been installed, 
the controller will indicate that the batch complete and the count will reset for the next cycle. If, after a good 
rundown, the operator runs the screwdriver in reverse, the batch count value will decrement by a count of 
one (based on the assumption that the operator is removing the last installed fastener). The batch count 
can be reset to begin a new batch by pressing ON/CLEAR key.

4.6.3 END OF BATCH RESET TIME (RT)

When a rundown batch is completed, the controller provides a visual indication (count = ‘00’) and audible 
indication (depending on audible settings) that the batch is complete, followed by a reset of the display 
count for the beginning of the next batch. The END OF BATCH RESET TIME value determines how long 
these indicators will stay on before the batch count resets. Please note that the screwdriver cannot be 
operated during this reset time period.

4.6.4 SLOW START TIME (RC) and SLOW START SPEED 
(SP)

Please refer to the section entitled ‘Screwdriver Speed Adjustments’ for further information on the Slow 
Start function.

Summary of Contents for 035/E32V

Page 1: ...OPERATORS MANUAL FOR ELECTRIC SCREWDRIVERS for self cutting Threaded Inserts ...

Page 2: ...NTROLLER 12 4 1 IMPORTANT INSTALLATION SAFETY 12 4 2 SPECIFICATIONS 13 4 3 GENERAL CONTROLLER OVERVIEW 15 4 4 GETTING STARTED 15 4 5 KEYPAD AND PROGRAMMING BASICS 16 4 6 PROGRAM OPTIONS AND EDITING 17 4 6 1 SEQUENCE NUMBER SL 17 4 6 2 BATCH COUNT SETTING SC 17 4 6 3 END OF BATCH RESET TIME RT 17 4 6 4 SLOW START TIME RC AND SLOW START SPEED SP 17 4 6 5 MAXIMUM AND MINIMUM RUNDOWN TIME SETTINGS HT ...

Page 3: ...misuse or lack of precautions previously brought to your attention Repairs will then be charged at cost including carriage The standard equipment is designed for reasonable use at an economic price Where this is of an exces sive nature either through continual use or the arduous nature of the operation the warranty period reduces accordingly Bossard and their suppliers if applicable will adopt a r...

Page 4: ...d maintenance of the machine you recently purchased from Bossard Before you operate the machine please ensure that you have read and fully understood this manual Should you have any questions or queries relating to the operation and use of this machine please contact your local Bossard customer service https www bossard com global en about us contact ...

Page 5: ...supply outlet is overload protected and of sufficient amperage capacity 6 Use only the correct plug for the controller and outlet Hold the plug of the power cord when connecting or disconnecting Do not pull on the cable 7 Do not expose the cable tool or controller to oil chemicals or heat Ensure that the cable is routed and used in such a manner as to not be subject to sharp objects that may abrad...

Page 6: ...ment parts and accessories with these tools and controllers 18 Any damage to the tool and or controller resulting from misuse abuse or failure to follow these guidelines will void the limited warranty period Grounding This controller and AC power cord is equipped with a 3 prong electrical receptacle plug with ground pin The controller must be connected to a properly grounded AC electrical outlet D...

Page 7: ...allation equipment by pushing or pulling depen ding on the model the outer sleeve of the bit holder to release the retainer Insert an appropriate power installation equipment release the sleeve and ensure that the installation equipment is properly locked in place by pulling back and forth on the installation equipment Screwdriver end of cable includes spring guard for added durability Push cable ...

Page 8: ... reverse to forward while the motor is running A protective circuit will stop the tool if it is inadvertently switched while running if this happens the trigger must be released and reactivated to continue operation 3 5 SETTING THE TORQUE An external torque adjustment nut located at the nose of the screwdriver is used to set the output torque of the screwdriver A reference scale 0 8 is available a...

Page 9: ...a tool balancer 4 Bit Holder Retract sleeve to Insert remove bits tool is inserted release the sleeve and pull back and forth on the bit tool to verify retention 5 Housing Nut Remove the housing nut to install a torque locking sleeve The lock sleeve covers the torque adjusting nut to deter unintentional changes to the adjustment 6 FWD REV Switch Select the desired direction of rotation for the scr...

Page 10: ...ewdriver 40V DC 71 221 IN LBS 8 0 25 0 Nm range 250 350 rpm 3 7 3 POWER SUPPLY CONTROLLER SPECIFICA TIONS One controller order separately is required per driver CE RoHS ETL Approved Model 035 E 32V BECT832N SSO is an optional count verify controller for the 035 E A 32VDC CESL8 series screwdrivers Please refer to the separate 035 E 32V BECT832N SSO Manual for further details and functionality 035 E...

Page 11: ...vers must be per formed by trained personnel knowledgeable and qualified in the repair of DC electric screwdrivers Use only genuine parts when servicing these products Do not attempt to modify the tools or controllers 3 11 WARRANTY The 035 E A CESL8 Series Tools and Controllers are warranted for one year from the date of purchase against defects in material and workmanship In addition the brushles...

Page 12: ...nd controllers to areas subject to airborne contaminants eg dust metal filings 4 Use only a properly grounded electrical outlet of the correct supply voltage to power the screwdriver controller 5 Ensure that the supply outlet is overload protected and of sufficient amperage capacity 6 Use only the correct plug for the controller and outlet Hold the plug of the power cord when connecting or disconn...

Page 13: ...connecting the screwdriver tool cable to from the controller 15 Turn the main power switch off when the controller is not being used Unplug the controller if it is not being used on a regular basis 16 Do not attempt to disassemble or repair the screwdriver or controller Repairs should only be per formed by qualified technicians properly trained in the safe operation troubleshooting and repair of t...

Page 14: ...m Settings selectable On sounds when Good No Good Batch Complete OF sounds when No Good FF sounds when Batch Complete No Good EF sounds when Good Batch Complete Input Connections Remote start remote reverse disable tool external confirm enable batch external clear Output Connections Rundown OK rundown NG batch complete Included Accessories AC power cord key for program lock user manual Dimensions ...

Page 15: ... being used an OUTPUT voltage must be set via a covered selection switch on the rear face of the controller Slightly loosen do not remove the two screws securing the OUTPUT cover in place Pivot the cover down and move the slide switch left 24 32V for 32VDC brushless screwdrivers or right 32 40V for 40VDC brushless screwdrivers Reposition and tighten the cover Connect the 6 pin cable of a compatibl...

Page 16: ...ng slow start etc Pressing ON from this mode will restore the display and added functionality Other uses of ON CLEAR are explained where required throughout this manual SELECT KEY The SELECT key is used primarily for entering the program editing mode and cycling through the available program settings Other uses of SELECT are explained where required throughout this manual UP DOWN ARROW KEYS The UP...

Page 17: ... COUNT SETTING SC Enter the desired number of fasteners to be installed per batch Depending on the setting of DIP switch 1 the display will either count down from the total batch value entered or count up to the total batch value The count will only increment and indicate GOOD rundown if the rundown cycle falls within the limits set by the min and max rundown time settings see below When all faste...

Page 18: ...rammed time window the rundown cycle will be accepted as GOOD OK and the batch count will increment MAX Time GOOD OK NO GOOD NG Time seconds 4 6 6 RECONFIRM TIME LL If the assembly process requires that the operator has the ability to double hit the fastener release and retrigger the screwdriver on a fastener that has just been installed a reconfirm time can be programmed into the control During t...

Page 19: ...le in steps from lowest L1 30 of full spd to highest L9 85 of full spd L0 equals 100 of run speed or slow start off Ht High Time and Lt Low Time The Ht and Lt settings establish a time window for OK NG evaluation of a fastener rundown Low Time Lt must be set to a value lower than High Time Ht during programming or an error Er will occur Ht value must be Lt Adjust value UP DOWN Adjust value UP DOWN...

Page 20: ...h trips for the preset amount of time LL must be set to 0 00 for the rt function to be available rr and rS Reverse Pause Tighten Entering a value greater than 0 00 for rr will start the cycle with a timed reverse rr value then forward until the clutch activates Note FWD REV switch must be in REV position for the function to work LL and rt must equal 0 00 for the rr to be available nS Disable Screw...

Page 21: ...f the batch is not completed within the tt time setting an alarm will sound and the display will flash tt until the operator runs the driver and completes the batch Only one of the two optional alarms can be selected for use Adjust value UP DOWN Press until dt or tt displays Release to view value Adjust value UP DOWN Toggle value Toggle value The controller also has a selectable slow start option ...

Page 22: ...30 85 of screwdriver free running speed rpm or L0 100 Exit the program mode and engage the start trigger or push mechanism on the screwdriver to check settings Repeat until the desired result is achieved Refer to the program flow chart for further details on entering parameters 4 6 9 AUDIBLE ALARM SETTINGS OK AND NG LIGHTS Along with the two digit count display the controller also provides visual ...

Page 23: ...23 4 6 10 INPUT OUTPUT CONNECTOR ...

Page 24: ...24 4 6 11 DIP SWITCH SETTINGS ...

Page 25: ...25 ...

Page 26: ...fy the tools or controllers 4 6 14 WARRANTY The 035 E 32V and 40V BECT832N 940 SSO controller is warranted for one year from the date of purchase against defects in material and workmanship This warranty does not cover damage due to transportation abuse misuse or improper service Our sole remedy is to repair or replace at our discretion any unit found to be defective due to defects in material or ...

Page 27: ...www bossard com 27 ...