13
• When Hr+ boost mode is activated, the On mode indicator will flash, together with the
current mode. e.g. If the current mode is auto mode, the On mode icon is flashing and Auto
mode icon remains on.
• For TPSE101, the display shows 0h, 1h, 2h, or 3h in boost mode. For TPSE201, the display
shows C1:h1
• Each press of
Hr+
will increase the duration of the override by 1 hour. Maximum duration is
3 hours. Pressing until the number rolls back to “0” will disable the Hr+ program override.
When Gravity-fed Hot Water System is selected, if the HW duration is shorter than the CH
duration, the HW duration will be set to the same duration of CH automatically.
• Press
Set
or wait 10 seconds without any key press to begin the period of override and return
to the home screen. A channel with override activated is turned on immediately; a channel
with override not activated will keep current operational status. The mode indicator(s) will
flash at the “on” position to indicate the temporary override.
• After 10 seconds, the clock is displayed with the Mode indicator(s) flashing to indicate that
the override mode is activated.
• CH or HW with override activated will return to the previous operating mode at the end of
the set duration and the corresponding Mode Indicator will stop flashing.
• When the Hr+ Program Override mode is activated and the clock is displayed, press
Hr+
to
review the current settings. “SET” is displayed, but there is no change of the internal count
down timer(s). If there is no further key press within 10 seconds, the clock will be displayed
again with the mode indicator(s) flashing.
• When reviewing the current settings, subsequent press of
Hr+
will add 1 hour to the internal
count down timer(s). Press
Set
or wait 10 seconds without further key press to start counting
down and return to the home screen. Pressing
Hr+
repeatedly until the duration becomes
“0” will stop the corresponding channel. When Gravity-fed Hot Water System is selected,
pressing of HW
Hr+
will set the duration the same as CH.
• The channel(s) will enter advance override mode when activated as above. The channel(s)
return to their previous set mode when user disables the advance override.
• The channels will function as above whether the program jumper is set to G or P.