background image

 

Continued 

 

 

 
 

4. 

Installing the Drain Outlet Clamp Assembly 

 

 

 

Select a location for the drain clamp 

above

 the ‘S’ Trap but not more than 40mm above 

the normal water level or the best location is on the transfer pipe between twin bowl sinks 
if you have one.  Position the drain outlet clamp on the drain pipe.  Allow adequate space 
for drilling.  Tighten Clamp with “Tightening Screw”  

 

 
Using the opening in the drain outlet clamp, drill a 

¼

” hole in the drain pipe.  Clean debris 

from the clamp.  Reattach tube Connector. 

 

NOTE:    Locate  the  drain  connection  away  from  the  garbage  disposal  to  prevent 

potential contamination and system fouling. 

 

 

 
 

 
 
 

Important: Use Cold Water Only! 

Page 6 

 

Summary of Contents for Genesis Cafe

Page 1: ...rse Osmosis System Model Genesis Cafe Congratulations on your purchase of the most advanced water purifier system available Installation and Service Guide PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION Page 1 ...

Page 2: ...ses parasites heavy metals inorganic chemicals pesticides and algae RO purifiers flush the impurities down the drain rather than collecting them in the filters as is the case with ordinary systems preventing any build up within the system Also RO systems oxygenate the water giving it a lively fresh taste unlike distilled water which may have a flat dead taste With REVERSE OSMOSIS you can be rest a...

Page 3: ...NOT USE THIS SYSTEM WHERE THE WATER IS MICROBIOLOGICALLY UNSAFE OR OF UKNOWN QUALITY WITHOUT FIRST CHECKING WITH YOUR DISTRIBUTOR THIS SYSTEM IS DESIGNED FOR USE ON POTABLE WATER WITHIN THE ABOVE CONDITIONS FOR OPERATION ROCAFE Reverse Osmosis Purifier The ROCAFE drinking water purifier represents the very latest in design and ultimately has become the standard for the drinking water industry The ...

Page 4: ... to 48 month INSTALLATION Preparation Check the following list of components to ensure that all parts are packed with your system 1 Storage Tank 1 RO System 1 RO Water Faucet 1 Installation Kit Determine the location for the installation of the RO system Avoid locations where the system might come in contact with hot water pipes or other hazards taking into consideration ease of maintenance Determ...

Page 5: ...changing cartridges The system will operate without problems laying on it s back 2 Shut off the Water Locate the water shut off valve for the cold water feed line you have selected for your water supply Accidentally hooking up the system to the hot water supply line will permanently damage the membrane To assure you are using the cold water line turn on both the hot and cold water faucets After th...

Page 6: ...l sinks if you have one Position the drain outlet clamp on the drain pipe Allow adequate space for drilling Tighten Clamp with Tightening Screw Using the opening in the drain outlet clamp drill a hole in the drain pipe Clean debris from the clamp Reattach tube Connector NOTE Locate the drain connection away from the garbage disposal to prevent potential contamination and system fouling Important U...

Page 7: ...ocking washer and then the thin threaded nut Tighten with a spanner Holding the tube from the filter system place the brass cup nut on first then the nylon olive and then insert the nylon thimble into the end of the tube as far as it will go Insert the tube into the base of the threaded part of the faucet push it in firmly about and slide nut up to thread and tighten firmly do not over tighten 6 S...

Page 8: ... to remove air bubbles trapped in system Do Not Use the First Reservoir of Water Allow the reservoir to fill for 1 to 2 hours Dispense this water to sink This process removes the factory installed sanitising solution from the entire system and sends it to the drain Repeat this process one more time Allow the tank to fill for 1 to 2 hours and dispense this water to the drain Allow to refill for 1 h...

Page 9: ...tank tap on handle should be in line with tubing as it enters the connection Not enough water Low water pressure If line pressure is below 40 PSI add a booster pump Not enough water Water supply is blocked Clear restriction rotate valve on feed water valve Not enough water Storage tank is depleted Consider an increase in tank size or membrane capacity Not enough water Clogged cartridges Replace Se...

Page 10: ...ng the cartridge into the housing tub and threading the housing tub back onto its housing head the by turning anti clockwise do not over tighten 9 Install the carbon chemical pre filter by installing the cartridge into the housing tub and threading the housing tub back onto its housing head the by turning anti clockwise do not over tighten 10 Turn Feed Water Valve ON with the faucet open run syste...

Page 11: ...emonstration models or to alternative brand or unbranded goods or to any replacement parts cartridges or components manufactured by and or sold by BOSS Water Systems Australia 3 This warrantee applies for a period of 12 months from the date of purchase of our product from an authorised dealer against defect in material of workmanship 4 The following damages and defects are excluded from this warra...