18
bosspoweredaccess.com
BoSS X-Series
User guide
4.6
Handset controller
The handset controller includes the platform
raise and lower controls.
Pressing the ‘UP’ button raises the platform.
Pressing the ‘DOWN’ button lowers the
platform.
Part way through the descent of the platform, a 3-second stop is
triggered to alert the operator to look down and around all 4 sides
of the platform to ensure that there are no people or obstacles
preventing the continued descent of the platform, thus averting any
risk of crushing or shearing.
Once the operator is sure that it is safe to continue the descent, the
‘DOWN’ button can be depressed a second time to continue the
lowering of the platform.
BoSS X-Series machines are fitted with a platform overload sensor.
If the platform load is exceeded the platform will not ascend and the
red LED indicator on top of the handset will illuminate.
4.7
Emergency stop
An emergency stop button is provided on the handset controller.
Once depressed this isolates the power to the raise and lower
functions.
To restore the power, twist the emergency stop button key clockwise
to release the button as shown below.
There is also an
emergency stop
button on the
chassis. Push in
to activate and
twist clockwise to
release.
BoSS_XSeries_Userguide_Rev C 0519_English.indd 18