g037975
Figure 12
1.
Bolt
4.
Control harness mounting
bracket
2.
Power/Ground connector
bracket
5.
Plow connector
3.
Power/ground connector
6.
Nut
13.
Mount the black and red power/ground
connector to the control harness mounting
bracket (
).
14.
Mount the relay pack under the hood using 1
sheet-metal screw (
).
Note:
Ensure that the relay pack is mounted
in the upright position.
g038169
Figure 13
1.
Relay pack
15.
Connect the black power/ground cable to the
negative (-) battery terminal (
g321799
Figure 14
1.
Black power/ground cable
5.
Vehicle battery
2.
Brown wire
6.
Battery cable
3.
Red fused wire
7.
Plow wire harness
4.
In-line fuse
16.
Connect the brown wire to the negative (-)
battery terminal (
).
17.
Connect the free end of the battery cable to the
positive (+) battery terminal (
18.
Connect the red, fused wire to the positive (+)
battery terminal (
).
19.
Secure all wiring in a position that avoids hot or
moving parts using cable ties.
Mounting the Plow
Controller
DANGER
The controller could cause serious injury if
contacted during a crash.
Mount the controller in a location that vehicle
occupants will not contact during a crash.
Mounting the UTV Controller
Note:
Mount the controller in the cab in a dry area
where it does not interfere with vehicle operation or
visibility.
Important:
Do not install the swivel mount when
temperatures are below 16°C (60°F).
1.
Park the machine on a level surface, shut off the
engine, wait for all moving parts to stop, engage
the parking brake, and remove the key from the
ignition switch.
2.
Determine the mounting location for the
controller.
11