2 1
Transport and assembly
4.7.3
Connection to compressed air
(right side of the machine, behind).
Procedure:
* Plug on supply hose (1),
* Tightly fasten the hose clip (2).
4.7.4
Testing the machine connection
* check voltages and phases,
* switch on the main switch on the control cabinet,
* check functions of light barrier and EMERGENCY-OFF,
(see chapter „Safety“ point 1.7.3),
*
check sense of rotation from the hydraulic motor
(red arrow),
fault of the pump.
Two persons are necessary to check sense of rotation.
The first person has to connect the motor (at the
operator´s desk) and the second person has to check
visual the sense of rotation of the motor on the ydraulic
aggregate.
If you cant see the arrow,
sense of rotation = clockwise.
* If sense of rotation is wrong: EMERGENCY-OFF
change rotary field, change L1 against L2, or L2
against L3 or L3 against L1. Test again,
* hydraulic aggregates with cooler and thermostat,
check the functioning of the ventilator
(set
thermostat to minimum). The blower must start at
approximate 30 °C.
fault of pump and valve unit.