TUMBLE DRYER
r120085e -15/12
04.99
Error
no.
Test / Procedure
Possible cause
Error display
Re 14
A
Door switch F1 and / or
locking mechanism
defective.
Remove plug X11–1 from
the power module.
Test switch, cable, plug and
mechanism
– Locking hook
– Bowden cable
– Door button
B
Power module defective.
Remove plug from the
power module, short-circuit
Pin 7 and 5 on plug-and-
socket connection X11–1 on
the power module and start
any drying programme.
If the appliance starts, the
power module is o.k.
15
Appliance does not
start.
Operating module defective.
Activate test mode;
If this mode can be
activated, the operating
module is o.k. Check
whether the circuit board
has become detached from
the operating module.
If not, continue with Error
number 15.
16
Button, display or
programme selection
malfunctions
occasionally.
Operating module or power
module defective.
Start “extra dry” and “very
dry” test programmes.
17
Filter LED flashes,
filter is clean.
A
Overheating
See Error number 4.
B
NTC R2 or NTC R4
defective.
Remove the cable from the
power module.
Test NTC, cable and plug-
and-socket connection.