6
Drum is not rotating.
A
Motor is not rotating
See Error number 7.
B
Belt loose, slipping or
defective.
Clamping device defective.
Test belt and clamping
device.
C
Drum blocked or
overloaded.
Test drum.
7
Motor is not rotating
– rotates only in one
direction,
– rotates constantly.
A
Motor, cable or plug-and-
socket connection defective.
Motor protector has been
actuated.
Motor capacitor defective.
Test motor, capacitor and
wiring.
B
Door switch defective.
See Error number 15.
C
Power module defective.
Start “BW cupboard dry”
test program and measure
drive voltage for motor.
Clockwise rotation:
Mains voltage between
X11–10.5 and X11–10.3;
Anti-clockwise rotation:
Mains voltage between
X11–10.5 and X11–10.4
Before performing this test,
remove the heater plug, as
thermal cut-out B9 will trip
immediately without the
motor.
8
Is not heating.
A
Thermal cut-out B9 has
tripped.
See Error number 13 B.
B
Heater defective.
Test heater and cable.
C
NTCs defective.
Test NTCs (cold resistance)
and wiring.