38
ELECTRICAL CONNECTIONS (FOR ENGINEERS ONLY)
6 720 644 593 (2010/04)
5.4.17 Configuration diagram 1-ACD p-v - solar water heating with 2nd collector array, swimming
pool (connected via valve) and external heat exchanger
Fig. 29
R1
Pump SP, solar circulation system
R2
Pump PD, heat exchanger
R3
Pump PA, 2nd collector array
R4
Valve DWUC for cylinder selection
R5
Valve DWUD, anti-icing system (option)
S1
Temperature sensor (T1), collector FSK, array 1
S2
Solar cylinder bottom temperature sensor (T2)
S3
Swimming pool temperature sensor
S4
Solar cylinder middle temperature sensor (option)
S5
Temperature sensor (TA), collector FSK, array 2
S6
Temperature sensor (TD), external heat exchanger
S7
Flow heat meter WMZ temperature sensor (option)
S8
Return heat meter WMZ temperature sensor (option)
WMZ
Heat meter (option)
WMZ
5
R1
S2
S3
S8
S7
R5
S1
R4
R2
S6
S4
R3
S5
7747006072-32.1 SD
S1 S2 S3 S4 S5 S6 S7 S8
I9
L
N
R1 N1 R2 N2 R3 R3 R4 R4 R5 R5
L3 N3 L4 N4 L5 N5
230V
AC
R4
R3
R5
R2
R1
S1 S2 S3 S4 S5 S6 S7 S8 WMZ