9
DETAILS OF THE PRODUCT
6 720 644 593 (2010/04)
2.4 Specifications
TDS 300 programmer
Power consumption
1.8 W
Enclosure rating
IP20 / DIN 40050
Supply voltage
230 V AC, 50 Hz
Operating current
I
max
: 5 A
Maximum power consumption
5 A (max. 1.1 A per output/1 device per output)
Sensing range
- 30 to + 180 °C
Permissible ambient temperature
0 to + 50 °C
Collector temperature sensor
NTC 20K with 2.5m cable
Cylinder temperature sensor
NTC 10K with 3m cable
Dimensions H x W x D
170 x 190 x 53 mm
Tab. 1
Specifications
Temperature sensor S1 (S5 with 2 arrays)
NTC 20K
Temperature sensor S2 ... S8 NTC 10K
T ( °C)
R (k
Ω
)
T ( °C)
R (k
Ω
)
T ( °C)
R (k
Ω
)
T ( °C)
R (k
Ω
)
-20
198.4
60
4.943
60
3.243
-10
112.4
70
3.478
70
2.332
0
66.05
80
2.492
0
35.975
80
1.704
10
40.03
90
1.816
10
22.763
90
1.262
20
25.03
100
1.344
20
14.772
100
0.95
30
16.09
110
1.009
30
9.786
110
40
10.61
120
0.767
40
6.653
120
50
7.116
130
0.591
50
4.608
125
Tab. 2
Resistances of the temperature sensors
The temperature sensors must be disconnected from the programmer for their
resistances to be measured.