16
INSTALLATION (FOR ENGINEERS ONLY)
6 720 644 593 (2010/04)
4.2.4 Installation for cylinder selection function
The “cylinder selection” function in a solar heating system requires a valve that directs the flow to the
cylinders according to the switching conditions and cylinder priority (
Æ
Section 9.5.18, page 68).
Fig. 9
Valve for cylinder selection
1
Solar system cylinder
2
Cylinder C
3
TDS 300solar heating programmer
B
Fit 3-way motorised valve in the flow pipe of the solar system according to the table below.
Mark
Connection
I
From collector array (flow)
II
To cylinder C
III
To solar system cylinder
Tab. 5
Connection markings on valve.
II
I
III
R1
DWUC
6720613732-10.1 SD
1
2
3