APPLIANCE INFORMATION
6 720 821 670 (2018/06)
9
LPG Appliances
DESCRIPTION
LPG
UNIT
9kW
12kW
15kW
18kW
21kW
24kW
Gas flow rate - Max. 10 minutes from lighting
Propane Gas (LPG)
kg/h
0.71
0.96
1.20
1.44
1.77
1.91
Central Heating
Max. rated heat input (net)
kW
9.24
12.32
15.40
18.48
21.54
24.62
Min. heat input
kW
5.95
5.95
5.95
9.64
9.64
9.64
Maximum rated heat output 40/30 °C
kW
9.64
12.85
16.06
19.28
22.47
25.67
Maximum rated heat output 50/30 °C
kW
9.55
12.74
15.92
19.11
22.27
25.45
Maximum rated heat output 80/60 °C
kW
9
12
15
18
21
24
Maximum flow temperature
°C
82
82
82
82
82
82
Maximum possible flow temperature
°C
87
87
87
87
87
87
Maximum permissible operating pressure
bar
2.5
2.5
2.5
2.5
2.5
2.5
Flue
Flue gas temp. 80/60 °C, rated/min. load
°C
59/57
62/57
66/59
71/61
75/64
79/64
Flue gas temp. 40/30 °C, rated/min. load
°C
40/35
43/35
46/36
49/37
52/37
55/38
CO
2
level at max. rated heat output (after 30 min)
%
10.5
10.5
10.5
10.5
10.5
10.5
CO
2
level at min. rated heat output (after 30 min)
%
10
10
10
10
10
10
NOx class
6
6
6
6
6
6
NOx rating
mg/kWh
36.0
38.6
44.3
48.7
55.5
56.0
Condensate
Maximum condensate rate
l/h
0.5
0.7
0.9
1.2
1.4
1.5
pH value, approx.
4.8
4.8
4.8
4.8
4.8
4.8
Electrical
Electrical power supply voltage
A.C. V
230
230
230
230
230
230
Frequency
Hz
50
50
50
50
50
50
Maximum power consumption
W
26
36
52
55
44
54
General data
Appliance protection rating
IP
20
20
20
20
20
20
Permissible ambient temperatures
°C
0 - 50
0 - 50
0 - 50
0 - 50
0 - 50
0 - 50
Nominal capacity of appliance
litre
1.1
1.1
1.1
1.1
1.1
1.1
Packaged appliance weight
kg
31
31
31
31
31
31
Total appliance weight
kg
27.4
27.4
27.4
27.4
27.4
27.4
Lift weight
kg
22.6
22.6
22.6
22.6
22.6
22.6
SEDBUK 2005
%
90.1
90.1
90.5
90.4
90.0
90.0
SEDBUK 2009
%
89.0
89.0
89.1
89.2
88.9
88.9
Flue system
Category II 2H 3P type C13, C33 & C53
Table 6 Technical data LPG