PRE-INSTALLATION
6 720 821 670 (2018/06)
24
High level horizontal flue
High level horizontal flue with additional elbows
High level horizontal flue with additional elbows
Vertical balanced flue assembly
Vertical balanced flue with elbow offset (2 x 90 ° bends)
Vertical balanced flue with elbow offset (2 x 45 ° bends)
Maximum flue length
(mm)
60/100
80/125
High level horizontal flue
4,600
13,000
Table 24
Maximum flue length
(mm)
60/100
80/125
High level horizontal flue with 2 x 90° bends
2,600
11,000
Table 25
Maximum flue length
(mm)
60/100
80/125
High level horizontal flue with 3 x 90° bends
N/A
9,000
Table 26
6720806945-22.1W
o
6720806945-23.1W
o
6720806945-24.1W
o
Maximum flue length
(mm)
60/100
80/125
Vertical balanced flue assembly
6,400
15,000
Table 27
Maximum flue length
(mm)
60/100
80/125
Vertical balanced flue with 2 x 90° bends
2,400
11,000
Table 28
Maximum flue length
(mm)
60/100
80/125
Vertical balanced flue with 2 x 45° bends
4,400
13,000
Table 29
6720806945-25.1W
o
A = 300 mm
B = 500 mm
6720806945-26.1W
o
6720806945-27.1W
o