Rev 0 (1/17/08)
20
WFMC Service Tips
WFMC Service Tips
–
–
Test Program (2B): Module Fault
Test Program (2B): Module Fault
Codes (Test 1)
Codes (Test 1)
Last 8 fault codes are
stored & displayed!
Test
P1:ERRORS
/
P:01
(Viewing control module fault codes) --
Start & end test
P1
(WFMC64/84) /
(P:01)
(WFMC32/33/53) by pushing
Start/Pause
button. Scroll through all fault codes by
pushing
Spin Selection
(WFMC32/33/53) or
Menu
(WFMC64/84) buttons.
•
WFMC32/33/53 displays alternate between fault code (e.g.
E:01
) & when fault occurred on in last 8
washes (e.g.
C:00
) – shows
C:00
if fault didn’t occur.
•
WFMC64/84 displays show fault code & when fault occurred in last 8 washes (e.g.
0 - Er:01
).
HINT: # of faults reads “
0
”
for faults which didn’t occur.
Scroll thru all faults and
look at # of faults to see
which faults occurred.
WFMC32/
WFXD52 Displays
WFMC64/
WFXD84 Displays
Test #
Problem
Possible Cause(s)
E:01
Er:01
washing
Door open
Door lock not engaged
Er:02
washing
Door lock can't be locked
Jammed lock or bad wire harness
E:03
Er:03
washing
Door lock can't be unlocked
Jammed lock or bad wire harness
E:04
Er:04
washing
Door control broken
Faulty Triac/control module or oversudsing
(washer locks, thinking it has overfilled)
E:05
Er:05
P:16
NTC open-circuited
Faulty NTC or bad wire harness
E:06
Er:06
P:16
NTC shorted
Faulty NTC or bad wire harness
E:07
Er:07
P:16
Unexpected heating (heater on at wrong time) Faulty heater or stuck heater relay
E:08
Er:08
P:16
Heater doesn't shut off
Faulty heater or stuck heater relay
E:09
Er:09
P:4
Communication lost to motor
Faulty wire harness
-----
Er:10
P:11
Flow meter gives wrong values
Faulty flow meter or wire harness
-----
Er:11
P:8/9/13
No water flow (within 6 minutes)
Faulty inlet valve, wire harness, hose
E:12
Er:12
P:8/9/13
Water supply time exceeded
Faulty inlet valve, wire harness, hose
E:13
Er:13
P:15
Drain pump time exceeded
Faulty drain pump, wire harness, hose
E:14
Er:14
P:9
Overflow level exceeded
Faulty/blocked pump, hose, inlet valve
-----
Er:15
P:8
Pressure sensor gives failure voltage level
Faulty pressure sensor, wire harness
-----
Er:16
P:8
Can't calibrate pressure sensor
Faulty pressure sensor, wire harness
E:20
Er:20
P:4
Spinning aborted due to unbalanced load
Unbalanced load or faulty wire harness
E:21
Er:21
Excessive foam
Wrong or too much detergent used
E:22
Er:22
washing
Frequency synchronization failed
Faulty control module
E:24
Er:24
P:4
Motor power relay failed
Faulty control module
NOTE: Fault codes stored in module can’t be cleared .
702_58300000133618_ara_en_a