Bosch Security Systems | 2004-06
EN
| 13
7902 - 7905
| Installation and Operational Manual
4. Rotary switch (designates the box to a camera input)
5. Tamper switch
6. Terminal block for optional Passive Infra-Red detector
Alarm input
The alarm/action box provides inputs for detectors with N.O. and
N.C. contacts. The figure above shows how they are connected to the
screw terminals of the box.
SETTINGS
Four switches - located inside the case, on the circuit board - are used
to configure the circuit according to the system.
•
The rotary switch designates the box to a particular camera input.
•
The three small slide switches have the following functions:
Restrictions:
•
Maximum one Alarm/Action Box and/or Intercom Box per
camera input.
•
Box always designated to camera in line.
•
Camera is always last in line.
Dedicated settings for Eazeo color systems:
Note:
•
When no detectors with N.C. contacts are used terminals
1
and
2
must be interconnected with a wire.
•
When no PIR detector is used terminals
NC
and – of
terminal block (6) must be interconnected with a wire.
Switch
Off
On
Description
1 BOX
1
2
number of accessories
2 TAMPER
TAMPER
OFF
tamper-switch
override
3 LAST
N