Page 1: ... Actie Module NL Manuale de installazione ed uso Scatola Allarme Action IT Manual de instalação e de instruções Caixa de Alarme Acção PT Manual de instalación y uso Caja de Alarma Acción ES Installations og betjeningsvejledning Alarm Handlingskasse DA Installations och bruksanvisning Larm Åtgärdsenhet SV Asennus ja käyttöohje Hälytys Toiminolaitteella SU Installasjons og bruksanvisning Alarm Handl...

Page 2: ...06 7902 7905 Installation and Operational Manual TABLE OF CONTENTS ENGLISH 1 FRANÇAIS 15 DEUTSCH 30 ESPAGÑOL 43 NEDERLANDS 58 ITALIANO 71 PORTUGUÊS 85 DANSK 98 SVENSKA 111 SUOMI 124 NORSK 136 GREEK 149 TECHNICAL SPECIFICATIONS 163 ...

Page 3: ...harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or telev...

Page 4: ...FCC rules under test conditions that included use of system cables and connectors between system components If you have any problems contact your dealer WARNINGS Any unauthorized modification to this equipment may cause violation of the FCC rules resulting in the revocation of the authorization to operate the equipment To prevent fire or shock hazard do not expose this accessory to rain or moistur...

Page 5: ...Box TABLE OF CONTENTS Introduction 4 Installation 6 Mounting the box Installation and setting of an optional Passive Infra Red PIR detector Location of the PIR Installation of the PIR PIR settings Walk test LED Pulse counter System cable Action output Alarm input Settings 13 Tamper switch active ...

Page 6: ...able 5 System cameras The following items are included in this kit 1 Alarm action box 1 System cable 5m 15ft 1 User manual 1 PIR unit for version with PIR 1 Cable 50 cm for interconnection between alarm action box and PIR for version with PIR Colour Observation Monitor 4 5 5 2 talk action menu _ next auto view Colour Observation system Colour Observation Monitor 4 4 4 4 4 4 4 3 1 R A E N R A F R A...

Page 7: ...or screen 2 Alarm This function provides alarm inputs to the security system All kinds of detectors having a N O or N C contact are supported for example infrared detectors smoke detectors magnetic door window contacts When a detector triggers the alarm action box the system monitor automatically switches to the camera input the alarm action box is designated to The system monitor produces an alar...

Page 8: ...onfiguration of the cameras and accessories connected to its inputs This is done automatically when the power is switched on Use the power switch to switch off Operating the power save key is not sufficient If switching off is impracticable use the auto install option of the system monitor s install menu Mounting the box 1 Loosen the screw holding the cover and remove the cover 2 Remove the circui...

Page 9: ...s of the circuit board switches to configure the box according to your system See section settings 7 Fit the cover and secure the screw holding it Installation and setting of an optional Passive Infra Red PIR detector Location of the PIR The position of the PIR determines its view Select a location where an eventual burglar is most likely to be detected Place the sensor at a height of 2 2 m to acc...

Page 10: ...tains potted plants furniture Installation of the PIR 1 Remove the fixation screw 1 and open the housing by releasing the locking latch 2 Both are located at the bottom of the unit 2 Remove the circuit board by loosening the fixation screw 1 3 Knock out the desired mounting holes 1 and wiring holes 2 in the bottom plate 4 Thread the wires through the knocked out wiring hole s 5 Fasten the bottom p...

Page 11: ...he alarm action box with the cable supplied see figure below Sensor height Maximum sensor range m Lens position 0 5 10 2 5 m 14 m 12 5 m 11 m 2 0 m 12 m 10 5 m 9 5 m 1 5 m 10 m 8 5 m 8 m 1 2 3 4 5 6 7 8 Terminal block for interconnection with alarm action box Lens position sensor range adjustment Jumper walk test LED activated deactivated Tamper switch PYRO sensor Jumper 1 2 or 3 pulse count Locki...

Page 12: ...tely 2 minutes after mains power on PIR settings There are 2 jumpers to set the PIR to your own requirements Walk test LED Pulse counter 1 2 or 3 See previous figure for the location of the jumpers Walk test LED jumper installed Walk test LED is activated When the PIR sensor is triggered the LED will light jumper not installed Walk test LED is deactivated Pulse counter Set this jumper to select th...

Page 13: ... For optimum picture and sound quality you should always use 4 wire dual twisted pair cable when extending the connection max 300m 900ft The cable and plugs are available in the hobby and professional trade Pay attention that the connectors are fixed to the cable corresponding to the figure below If the cable length between monitor and camera exeeds 200m 600ft after an accessory is inserted in the...

Page 14: ...ction output The figure below shows the screw terminals to which for example a door opener circuit can be connected 1 System cable input 2 System cable output 3 Switches 1 2 3 CAUTION The plugs used for the observation system have the same dimensions as standard telephone plugs Never connect the security system with telephone equipment 6 CL 66610005_505 AI 1 2 3 7 6 8 9 4 0 1 2 3 5 4 5 2 1 3 CAMER...

Page 15: ... the circuit according to the system The rotary switch designates the box to a particular camera input The three small slide switches have the following functions Restrictions Maximum one Alarm Action Box and or Intercom Box per camera input Box always designated to camera in line Camera is always last in line Dedicated settings for Eazeo color systems Note When no detectors with N C contacts are ...

Page 16: ...ch active On the circuit board a tamper switch secures the box When opening the box this switch triggers an alarm on the monitor To suppress a continuous alarm message while servicing the system the tamper switch override is set in the OFF position CAUTION Don t forget to reactivate the tamper switch by switching the override to the TAMPER position 1 Any position 2 OFF tamper switch active ON over...

Page 17: ...able 24VDC Contact rating action relay 30V 5A AC DC Alarm input trigger threshold 150 Ohm N C input 150 Ohm N O input System connectors RJ11E modular telephone connectors System cable 4 wire dual twisted pair cable e g VSS2906 00 or VSS2930 00 PIR angle of sight horizontal vertical 110º 20º Dimensions without PIR 119 x 77 x 40 mm Ambient conditions Ammonia resistant Temperature operating 10ºC 45ºC...

Page 18: ... V Subject to change Printed in Portugal Bosch Sicherheitssysteme GmbH Ludwig Bölkow Allee 85521 Ottobrunn Germany www bosch sicherheitssysteme de Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands www boschsecuritysystems com ...