Circuit diagrams
6 720 648 162 (2011/08)
Fig. 73 Circuit diagram 2
Quick connect plug
Terminal strip on Riello Burner
Hot Neutral
Service
Switch
Fuse
Red wire -
NOT USED IN
THIS
APPLICATION
Riello F3 or F5 Series Oil Burner Wiring
6 720 648 162-20.1T
Riello F3 or F5 Series Oil fired Burner
Using a L8148A Aquastat -
1) Connect room thermostat or end switch wiring to the T & TV terminals of the L8148A Aquastat.
2) Connect incoming 120 Vac power source to L1 on the L8148A.
3) Connect a neutral to „L2“ on the L8148A.
4) Connect black wire to terminal B1 of the L8148A and to the „L“ terminal on the Riello Burner terminal block.
5) Connect black wire to terminal B2 of the L8148A and to the „N“ terminal on the Riello Burner terminal block.
6) Connect green wire to ground screw on L8148A and to ground connection on Riello Burner.
7) Red wire is not used in this application.
Note: This drawing is conceptual in nature and does nit purport to address all design, installation or safety considerations. Additional
safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers. It
is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications
involved.