34
|
Installing the boiler
6 720 648 162 (2011/08)
6.5
Connecting the fuel supply
Make the fuel connection in accordance with all
applicable local and national codes and regulations. We
recommend fitting a fuel filter and de-aerator for oil
boilers.
B
Visually inspect the fuel pipe and clean or replace, if
necessary.
B
Install a shut-off valve into the fuel supply pipe.
B
Connect the fuel pipe free of stress to the boiler.
B
Check the fuel line for leaks.
6.6
Installing aquastat
An aquastat controls the boiler supply temperature.
B
Install aquastats in the sensor well as specified by the
installation manual.
For operating the boiler with aquastat
Æ
Chapter 7,
page 36.
Fig. 52 Installling aquastat
1
Immersion sleeve
6.7
Blocked vent switch (required in
Canada)
For Canadian installations fit a blocked vent switch per
the vent switch manufacturer’s instructions and as close
as possible to the boiler breach.
See wiring diagrams.
6.8
Electrical connections
B
Remove rear boiler jacket.
–
Unscrew the fixing screws.
B
Remove Back boiler cover. Wiring from the control/
aquastat to the burner is passed through the hole in
the front boiler top panel.
Fig. 53 Removing/Installing the back boiler cover
1
Back boiler cover
For details of the correct writing see aquastats/control
documentation.
1
6 720 648 030-12.1T
DANGER:
Risk of death from electric shock.
B
Electrical work may only be carried out by
qualified technicians. Before opening any
electrical equipment, isolate it from the
power supply by turning off the
emergency shut-off switch or
disengaging the heating system circuit
breaker, and prevent from accidental
reactivation. Follow the installation
instructions.
1
6 720 648 162-01.1T