Feed-through cables
Feed-through power cables
Power into the housings must be supplied using type UL Standard SJ cord (or better)
acceptable for outdoor use. Installation must conform to NEC 400-4 CEC rule 4-010 and be
marked with OUTDOOR, W, or W-A.
The supplied cable glands have the following specifications:
Gland type
Cable clamping range
3/8-in. NPT
4.5 to 7.9 mm Ø
1/2-in. NPT
5.8 to 10 mm Ø
M20 x 1.5
3.5 to 8 mm Ø
Feed-through wiring through the base
To feed cabling through the base of the housing:
1.
Remove the two dome plugs located at the bottom the housing.
2.
Screw the two 3/8-in NPT fittings into the foot of the housing.
3.
Attach the foot of the housing to the mount.
4.
Feed the power and video cables through separate cable glands into the housing.
5.
Ensure that the holes in the rear are covered with the rubber plugs provided.
Feed-through wiring through the rear
The rear holes allow cable to be fed through the supplied glands or the direct connection of
conduit fittings.
1.
Remove the dome plugs located at the rear the housing.
2.
Screw the cable glands into the holes at the rear of the housing. The holes accept either
3/8‑in NPT or 1/2‑in NPT cable glands or conduit fittings. (The M20 x 1.5 cable gland can
also be used.)
3.
Feed the power and video cables through separate cable glands into the housing.
4.
Ensure that the holes in the bottom of the housing are covered with the rubber plugs
provided.
5.4
5.4.1
5.4.2
5.4.3
UHO Camera Housing
Installation | en
13
Bosch Security Systems
Installation Manual
2014.10 | 5.0 | F.01U.167.418