815_58300000120057_ara_en_d.doc – 25.05.11
Seite 35 von 60
6.5
Removing and installing circulation pump
6.5.1 Removal
►
Remove side panels and base plate
►
Loosen connection between stainless steel container and plastic
base pan, (2 screws at front and 2 screws at rear)
►
Place appliance on its rear panel
►
Fold down the base pan
►
Using a screwdriver, press the clip on the right side of the
circulation pump inwards
►
Rotate pump to the right
►
Remove pump.
6.5.2 Installation
►
Prior to installation, lubricate the seal with washing-up liquid.
►
Connect pump to the pump housing
Leaks
►
Ensure that all 4 locking hooks in the pump housing
are attached
Sluggish or blocked fan impeller
►
When the pump is changed, the spacer ring attached
to the motor shaft must be transferred to the new
pump
►
Rotate pump to the left into the pump housing until the clip
engages
►
Fold up the base pan and install appliance
►
Screw stainless steel container to the base pan
►
Screw on base plate and side panels
6.5.3
Removing the slide ring seal
►
Remove circulation pump
►
Loosen fan impeller, locking the rotor with a pen or screwdriver
►
Remove pump housing
►
Remove slide ring seal