815_58300000120057_ara_en_d.doc – 25.05.11
Seite 15 von 60
4.7
Salt and rinse-aid indicators (optional)
The dispenser contains a float with an integrated permanent magnet
(A). The magnetic field actuates a reed switch on the outside of the
dispenser. The lamps of the refill indicators in the control panel are
switched on via this reed switch.
A Permanent
magnet
B Reed switch open
C Reed switch closed