120
en | Troubleshooting Guide
VG4 Modular Camera System
F.01U.133.268 | 6.0 | 2010.03
User’s Manual
Bosch Security Systems, Inc.
11.2
VG4 IP AutoDome Video and Control
Inside of
EnviroDome bubble
is foggy
–
Check the status of the Heater Module (
ON
-
66
-
ENTER
).
If status reports Heater No Power, then:
–
Turn off the power to the AutDome.
–
Check the FX103 fuse in the Power Supply Box for power (24 V) to the heater module.
If O.K., then:
–
Check all wiring and connector pins to the heater module.
Low Voltage flashing
on monitor display
–
If using a non-Bosch power supply, confirm that it meets the Bosch AutoDome power
ratings. See the AutoDome Datasheet for specifications.
If O.K., then:
–
Check the mains input line voltage.
If O.K., then:
–
Check that the maximum wire length from the power supply has not been exceeded.
See the
AutoDome Modular Camera System Installation Manual
.
If O.K., then:
–
Measure the AC voltage input to the camera while power is applied to the camera. The
voltage must be ≥ 21 VAC to stop the message.
Problem
Solution
No Network
Connection
–
Check all network connections
–
Ensure that the maximum distance between any two Ethernet connections is 100
m (328 ft) or less.
Refer to the
AutoDome Modular Camera System Installation Manual
for more infor-
mation.
If O.K., then:
–
If you are behind a firewall, ensure that the Video Transmission mode is set to UDP.
a.
Access the Settings Web page for the IP-enabled device.
b.
Expand the Service Settings link, then click Network.
c.
Select UDP from the Video Transmission drop-down list. Then click Set.
Summary of Contents for series VG4-300