Security Escort
System menus and dialogs | en
195
Robert Bosch (SEA) Pte Ltd
Technical Reference Manual
2018.03 | SE3v1.0 | DOC
Element
Usage/Description
[Not Responding Map]
To assist in diagnosing problems with the SE receivers associated
with an SE coordinator, several commands can be issued from the
Central Console to requesting information from the SE
coordinator. This button requests a map of all the devices on this
SE coordinator that are not responding to the system. The current
troubles list is automatically updated.
[Out of Service Map]
This button requests a map of all devices on this SE coordinator
that were manually taken out of service to the system. The current
troubles list is automatically updated.
[Reset Transponder
Troubles]
This button is used to reset all of the alarm, test and message
counters to zero, and to remove any restoration reports.
[Jamming Map]
This button requests a map of all the SE receivers on this SE
coordinator that are reporting a jamming condition to the system.
The
Current Troubles
list is automatically updated.
[Tamper Map]
This button requests a map of all the devices on this SE
coordinator that are reporting a tamper condition to the system.
The current troubles list is automatically updated.
[Input 1 Map]
This button requests a map of all Input 1s on this SE coordinator
that are reporting an activation to the system. The current troubles
list is automatically updated.
[Input 2 Map]
This button requests a map of all the Input 2s on this SE
coordinator that are reporting an activation to the system. The
current troubles list is automatically updated.
[Previous]
Returns to the previous SE coordinator.
[Next]
Advances to the next SE coordinator.
[Acknowledge]
Clicking this button removes all restored troubles from the current
troubles list.
[Refresh Data]
Clicking this button updates all of the SE coordinator level data in
this screen. It does not update the device troubles (use stress test
or auto scan to update the device troubles).
[Cancel]
Clicking this button cancels all commands and closes the dialog
window.
10.4.6
Transponder parameter change
This dialog allows parameters stored in the SE coordinator’s EEPROM memory to be viewed
and changed.