Security Escort
System wiring | en
39
Robert Bosch (SEA) Pte Ltd
Technical Reference Manual
2018.03 | SE3v1.0 | DOC
The SE receivers use addresses 1 to 15. Configure the four switches from the left, 1, 2, 3 and
4 of dip switch ADDR as the address of the device.
Address
Switch Number on Dip Switch ADDR
1
2
3
4
0
(used for coordinator only)
OFF
OFF
OFF
OFF
1
(default setting for receiver)
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
9
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
Tab.
5.3:
Address settings on dip switch ADDR
Setting the jumpers for RS-485
For RS-485 communication, it is necessary to include the end of line jumper settings on the
last SE receiver to have a stable communication channel. Set the jumper for the SE
coordinator and the SE receivers as of below:
1.
For the SE coordinator and the last SE receiver only, locate the jumper block J5 and set
the jumper over the jumper pins 1 and 2. This is the default factory setting on the SE
coordinators/SE receivers.