When testing the receiver, power up the compatible control panel in which the receiver is
connected to and observe the LED behavior on the receiver.
–
Local walk testing can be performed on the motion detectors as defined in the tritech
and PIR chapters of this guide.
–
Magnet testing can be performed by opening or closing the door/window in which the
magnet is installed on.
2.6
Maintenance
It is recommended to check the battery of each device annually. This will ensure proper
operation and functionality of the devices.
Battery Life Extension feature (PIR and TriTech)
In the normal operating mode, an alarm can be transmitted only after three (3) minutes have
passed since the previous alarm restoral. This 3 minute lockout time reduces unnecessary RF
transmissions in high traffic areas, thereby extending battery life.