RE 30162-B/04.11 | SYHNC100-SEK...X
Bosch Rexroth AG
39/
44
Maintenance and repair
Maintenance and repair
9
Cleaning and care
9.1
NOTE
Failures!
Loss of functionality due to penetrating dirt and humidity!
Always provide for absolute cleanness when working on the SYHNC100-
f
SEK...3X..
Only use a dry and dust-free cloth for all cleaning works.
f
Aggressive detergents may damage the SYHNC100-SEK...3X and let it age
faster. Never use solvents or aggressive detergents.
For cleaning and maintenance proceed as follows:
Perform a visual inspection for checking the tight seat of all lines and screws.
f
Check all plug-in and clamping connections of the SYHNC100-SEK...3X for
f
correct seat and damage at least once per year.
Check lines for breakage and squeezing. Have damaged or defective lines
f
exchanged immediately!
Clean housing parts with a dry and dust-free cloth.
f
Maintenance
9.2
The maintenance of the SYHNC100-SEK...3X is limited to the cleaning of the
surface in order to prevent dirt and humidity from entering the housing. Regularly
check the SYHNC100-SEK...3X for dirt and correct connections taking into
account the environmental conditions.
Repair
9.3
The SYHNC100-SEK...3X can only be exchanged as whole unit. For safety
reasons, modifications at the SYHNC100-SEK...3X performed to one's own
authority are not admissible! Repair and maintenance works may only be
performed by Bosch Rexroth AG. For repair and maintenance works, send the
unit to the service address specified in chapter 15.
Devices returned to Bosch Rexroth for repair must be sent in geniune packaging.
Repaired devices are returned with default settings.
User-specific settings are not accepted. The user must transfer all appropriate
user parameters and programs again.