8.1 Operating the optional manual override
Valve type
M-.SED 6...N9VE1
is equipped with a manual
override. Using this manual override, the switching func-
tion of the valve can also be triggered if the valve solenoid is
not energized.
The manual override is only intended for manual operation.
The manual override is located on the side of the valve sole-
noid facing away from the valve.
IMPORTANT
With directional valves
M-.SED 6...VE1
, the manual over-
ride is only useful if the pressure in the tank channel of the
valve does not exceed 50 bar. Above this pressure value,
the required actuating force is too large and there is a risk of
injury if the tool slips.
DANGER
Only operate the manual override if it is ensured that
this will not trigger any dangerous working movement
of the connected actuator!
CAUTION
Do not use sharp-edged tools to operate the man-
ual override!
There is a risk of damaging sealing surfaces at the
valve solenoid.
The manual override is only intended for short-term
manual actuation and must not be brought into a certain
spool position for a longer period or permanently by
means of mechanical equipment.
The manual override is not suitable for frequently recur-
ring manual operations!
➢
Using a rounded tool with a maximum diameter of 3 mm,
push the manual override in the direction of the valve
housing.