13 Error causes and troubleshooting
Errors
Actions for troubleshooting
Reduced performance
Ensure that the load of the Compact Flash cards
does not exceed 70%
Reduced performance and damage to files or the
file system
Use released Compact Flash cards only
Use only similar and released Compact Flash cards
if two Compact Flash cards are required in one de-
vice
The system freezes or a "blue screen" appears. In
rare cases, the file system or the Compact Flash
card can be destroyed.
This can cause, among other things, uncontrolled
machine movements and data loss
Before inserting or removing the Compact Flash
card, do switch off the device!
Tab. 13-1: Error causes and troubleshooting
For information on errors that are displayed via the LEDs, please refer to
9.4 "Ethernet interfaces X7E1, X7E2 and XETH1" on page 14
"Operating and error display" on page 26
.
Repairs at the device by the customer are not permitted. Exceptions
are maintenance works listed in the chapter "Maintenance".
For further information in the event of repair, please contact the
Bosch Rexroth Service.
14 Maintenance
Lethal danger due to electric shock while open-
ing the housing!
WARNING
The LC display in the Embedded Terminal is operated with high voltage (de-
pends on the display type). Do not open the housing.
Only the maintenance works at the device listed in this chapter are
permitted.
For further information in the event of repair, please contact the
Bosch Rexroth Service.
Bosch Rexroth AG
Maintenance
Embedded Terminals with Profibus DP
Master
32/41
DOK-CONTRL-VEP*XX.5***-IT01-EN-P