Wrong settings of resolution and color may de-
stroy the monitor!
NOTICE
Observe the technical data of the monitor and adapt the operating system set-
tings accordingly.
The BIOS is configured and thus ensures that all connected output
devices can be controlled while booting.
Exception: An operator display and a DVI monitor are connected. In
this case, the image is only output on the DVI monitor while booting.
If the operator display does not output an image, set the image out-
put manually. There are two options:
1. Click on the icon of the graphics driver and select "Graphic
properties". Select and confirm "Intel Dual Display Clone" un-
der "Multiple displays".
Fig. 9-3: Graphics driver icon in the task bar
2. Under Windows, use the shortcuts <Ctrl>+<Alt>+<F4> to switch
between the DVI monitor and the VDP operator display. To start
the image output on an analog monitor, press <Ctrl><Alt><F1>.
The graphics driver stores the last output device. After a restart, the
images are only output on the last saved output device.
9.7 CDI interfaces XVID and XSER
The CDI interface is assigned to the two RJ45 sockets XSER and XVID. Connect
the operator display to these sockets. The corresponding cables are available as
accessories, see
chapter 5.4 "Connecting cables for the CDI interface" on page
The CDI interface includes the data interface (XSER) as well as the image inter-
face (XVID).
The USB signals and the digital data (touch, M-keys, LEDs and control signals)
are transferred via the data interface.
The DVI signals are transferred via the display interface.
To avoid malfunctions, use only cables listed in
necting cables for the CDI interface" on page 6
.
The CDI interfaces are color-coded on the device:
Bosch Rexroth AG
Interfaces
Control Cabinet PC
18/57
DOK-SUPPL*-VPB*40.3***-IT05-EN-P
Summary of Contents for Rexroth IndraControl VPB 40.3
Page 1: ...IndraControl VPB 40 3 Control Cabinet PC Operating Instructions R911336750 Edition 05 ...
Page 6: ...Bosch Rexroth AG Control Cabinet PC IV DOK SUPPL VPB 40 3 IT05 EN P ...
Page 61: ...Control Cabinet PC Bosch Rexroth AG DOK SUPPL VPB 40 3 IT05 EN P 55 57 ...
Page 62: ...Bosch Rexroth AG Control Cabinet PC 56 57 DOK SUPPL VPB 40 3 IT05 EN P ...