STOP Button of the Hand-Held Terminals IndraControl VEH 30.1, VEH 30.2 or VCH 08.1
The connection module for the hand-held terminals VEH 30.1, VEH 30.2 or
VCH 08.1 is equipped with an automatic STOP circuit jumpering. Thus, the
operator can connect or disconnect the hand-held terminals IndraControl VCH
08.1, VEH 30.1 or VEH 30.2 via the connection module without causing an
unintended stopping of the installation.
Shutdown of the plant due to connecting an In‐
draControl VEH 30.1, VEH 30.2 or VCH 08.1
with pressed STOP button.
NOTICE
Before commissioning the IndraControl VEH 30.1, VEH 30.2 or VCH 08.1 ob‐
serve that the STOP button is NOT pressed.
For more detailed information about the safety concept and the
connection of the stop and enabling circuits of the IndraCon‐
trol VEH 30.1, VEH 30.2 or the VCH 08.1, please refer to the
documentations for the hand-held terminals IndraControl VEH 30.1
(DOK-SUPPL*-VEH*30.1***-PR02-EN-P), IndraControl VEH 30.2
(DOK-SUPPL*-VEH*30.2***-PR01-EN-P)
or
IndraControl
VCH 08.1 (DOK-SUPPL*-VCH*08.1***-PR01-EN-P).
6.2.8
Pushbuttons on the VAM12.1-PB-NF-NN-TB-VD-NN-1608-NN and
VAM42.1-PB-NF-NN-TB-VD-NN-1608-NN
The VAM 42.1 features six pushbuttons. The VAM 12.1 features four pushbut‐
tons. There are no no. 3 and no. 6 pushbuttons.
4
5
6
1
2
3
Fig.6-13:
Equipment of the pushbuttons
No.
Actuators
Switching element
1
Color: White, illuminated
1 N/O contact
2
Color: White, illuminated
1 N/O contact
3 (not for VAM 12.1) Color: White, illuminated
1 N/O contact
4
Color: Red, not illuminated
1 N/C contact
Bosch Rexroth AG
DOK-SUPPL*-VAM*XX.1***-PR02-EN-P
Rexroth IndraControl VAM 12.1/42.1 Machine Control Panels
50/93
Module Design