62/80
Maintenance and repair
Bosch Rexroth AB,
Installation and maintenance manual, Hägglunds DOb, RE 15327-WA/05.2017
10 Maintenance and repair
10.1 Maintenance log
We recommend that a maintenance log is kept to record service/maintenance/repair,
addition and alteration of the equipment. Each note, observation or comment should
be dated.
10.2 Preventive maintenance
Common
The maintenance of hydraulic systems is designed to prevent failure of the system
and to keep the system running efficiently to specification. The specific procedures
will depend on the nature of the equipment, the environment it is working in and
the duty cycle, bearing in mind the consequences of a breakdown. To optimise
the maintenance intervals economically a Life Cycle Cost (LCC) analysis is
recommended.
Follow the
during the checks.
The panels covering the drive unit can be dismounted to simplify the access to the
components inside the unit.
Daily checks, first week after commissioning
Fluid leaks
Fluid level in the tank
Operating temperature
System pressure
System performance and general condition
Unusual noises
Contamination indicators on the filters
Pre-start checks (even daily)
Fluid leaks
Fluid level in the tank
Contamination indicator on the filters
Frequent checks
Unusual vibrations or noises
Fluid leaks
Fluid level in the tank
The unit is clean
The air flow paths not are blocked
Pressure levels normal - stable
Operating temperature
The drive is running smoothly
Contamination indicators on the filters
Check and clean the oil pan