![Bosch Rexroth Hagglunds DOb Installation And Maintenance Manual Download Page 17](http://html.mh-extra.com/html/bosch/rexroth-hagglunds-dob/rexroth-hagglunds-dob_installation-and-maintenance-manual_40577017.webp)
Delivery contents
17/80
Hägglunds DOb, RE 15327-WA/05.2017, Installation and maintenance manual,
Bosch Rexroth AB
5.4
Hydraulic fluids
The Hägglunds hydraulic system is primarily designed for operation with hydraulic
fluids according to ISO 11158 HM.
Fluids by the standards given in
Table 4: Suggested fluid types
are suggested.
Before the start of project planning, see data sheet RE 15414, Hydraulic fluid
quick reference, for detailed information on hydraulic fluids and specific additional
demands
Table 4:
Suggested fluid types
So 11158
ISo 15380
ISo 12922
HM
HEES
HFB
HV
HEPG
HFC
HEPR
HFDU
Details regarding the selection of hydraulic fluid
The hydraulic fluid should be selected such that the operating viscosity in the
temperature range, as measured in the motor housing, is within optimum operation
range, see
Fig. 3: Selection diagram for viscosity ranges with straight fluids, i.e.
General recommendation is to have a system temperature of
50°C, see dotted line in
Fig. 3: Selection diagram for viscosity ranges with straight
fluids, i.e. viscosity index 100
. A VG 68 fluid will render just above 40 cSt at this
point.
• Optimum viscosity range is 40 to 150 cSt.
• Running above 150 cSt or below 40 cSt results in reduced efficiency.
• Running above 400 cSt results in substantial efficiency loss.
• For pumps, the maximum start-up viscosity is 1600 cSt.
• Running below 30cSt may impact the system service life.
• Running below 20 cSt may render instant system seizure.