3-2
Ratings and Dimensions
Rexroth EcoDrive 03 DKC**.3-016
DOK-ECODR3-DKC16*UL***-IB01-EN-P
Description Symbol Unit DKC
**
.3-016
power dissipation at continuous current I
out_cont
and
continuous DC bus power P
DC_cont
respectively (UL)
14)
P
Diss_cont
W
130
1) 2) 3)
housing dimension; see related dimension sheet also
4) 5)
see fig. "Air inlet and outlet of drive controller"
6)
observe supply voltage for motor holding brakes
7)
find value for control section in project planning manual
8)
Suitable for use on a circuit capable of delivering not more than this
SCCR value, 600 V AC or less. The drive series shall be used with
listed AC input line fuses or listed circuit breakers specified in this
documentation.
9)
Mains input L1, L2, L3
10)
at P
DC_cont
11)
class J branch circuit fuse
12)
find value for tightening torque in project planning manual, electrical
terminals
13)
copper wire; PVC-insulation (conductor temperature 90 °C); Table
13.5.1; Ta
≤
40 °C
14)
plus dissipation of braking resistor
Abb. 3-1:
UL ratings and dimensions
A:
air intake
B:
air outlet
C:
mounting surface in control cabinet
d
top
:
distance top
d
bot
:
distance bottom
Fig. 3-2:
Air intake and air outlet at drive controller
Distances