IP Camera 200 Series
Advanced Mode | en
77
Bosch Security Systems
Installation and Operation Manual
AR18-10-B012 | v1.5 | 2011.01
Relay follows
If required, select a specific event that will trigger the relay. The
following events are possible triggers:
–
Off
: Relay is not triggered by events
–
Connection
: Trigger whenever a connection is made
–
Video alarm %s
Trigger by interruption of the video signal
–
Motion alarm %s
Trigger by motion alarm, as configured on
the
VCA
page
–
Local input %s
Trigger by the corresponding external alarm
input
–
Remote input %s
: Trigger by remote station's
corresponding switching contact (only if a connection
exists)
Relay name
The relay can be assigned a name here. The name is shown on
the button next to
Trigger relay
. The
LIVEPAGE
can also be
configured to display the name next to the relay icon. (Do not
use any special characters, for example &.)
Trigger relay
Click the button to switch the relay manually (for example, for
testing purposes or to operate a door opener).