Diagnostics
Thermal Camera Test
Pattern
On/Off
Focus / Iris: Save and Exit
Alarm Status
Enters the Alarm Status menu and displays the real time status of alarm inputs and outputs.
Alarm Inputs 1 to 8, Alarm Outputs 1 to 2 (Closed or Open)
BIST
Enters the Perform Built-in Self Tests menu. YES to start test. If confirmed, the BIST tests
start and the results are displayed. Typical results are:
Data Flash: PASS
FPGA: PASS
Bilinx: PASS
Internal Temp.
Displays the current temperature of the camera, in degress Fahrenheit and in degrees Celsius.
High Temp Events
Displays the number of times that the threshold of high temperature was exceeded.
Highest Temp
Displays the highest temperature reached, in degrees Fahrenheit and in degress Celsius.
Low Temp Events
Displays the number of times that the threshold of low temperature was exceeded.
Lowest Temp
Displays the lowest temperature reached, in degrees Fahrenheit and in degress Celsius.
Internal Humidity
Displays the percentage of humidity inside the camera housing.
Humidity Events
Displays the number of times that the threshold of the humidity inside the camera housing
was exceeded.
Security Access
Displays the number of times that the locked-command menu is unlocked.
CTFID Access
Displays the number of times that the Configuration Tool is accessed.
Restart Events
Displays the number of restart events.